Quick Links

QUICK INSTALLATION
Step 1. Select Location
Paintings
Step 2. Select Operating Mode (refer to table 1)
LOOP 1 is for High Security (Fast Trigger) applications and should ONLY be used if the asset will NOT
be subject to external vibration. Loop 2 (Standard Security mode) should be used in most cases.
Painting
1-3 Seconds
High Security (Fast Trigger) Mode (Loop 1)
Large Screen
5-8 Seconds
TV
Standard Security Mode (Loop 2)
Step 3. Program Device
SENSOR
1. Pull tab to activate battery
Step 4. Install Device
1. Clean mounting surface
(refer to mounting notes)
PLEASE SEE BOTTOM OF
PAGE 2 FOR FCC / IC
AGENCY STATEMENTS
Wireless Indoor Asset Protection Device
Wireless Indoor Asset Protection Device
Wireless Indoor Asset Protection Device
Wireless Indoor Asset Protection Device
INSTALLATION AND SETUP GUIDE
Gun Case/Safe
LOOP 1
LOOP 2
(refer to Programming Section)
2. Enter Zone Number, Zone Type,
TAB
PULL TO CONNECT BATTERY
Pull tab
(Asset)
Mounting
Surface
2. Peel tape backing before
installing. Place onto asset.
3. Rotate into position
Large Screen
TV
Computers
Jewelry
Box
Valuables
LOOP 3
O
30
MOUNT HORIZONTALLY ONLY (LOOP 3 ONLY)
Jewelry Box
Tilt Mode (Loop 3)
Input Type at Keypad
Enroll Serial Number
(press tamper switch)
Enter Loop Number at Keypad
(use Loop 2 unless Fast Trigger
or Tilt is required)
Peel here
K14379V3 7/11 Rev. A
5 5 5 5 870API
870API
870API
870API
Avoid sources of vibration (i.e. speakers,
fans, motors)
Choose a stable, clean, flat surface
Mount in an inconspicuous area.
FAULT
LOOP 3
O
30
OR
NORMAL
O
Greater than 30
LOOP 3
O
30
4. Press down firmly for 5 sec.
Step 5.
Test System

Advertisement

loading

Summary of Contents for Honeywell 5870API

  • Page 1 PLEASE SEE BOTTOM OF PAGE 2 FOR FCC / IC K14379V3 7/11 Rev. A AGENCY STATEMENTS 5 5 5 5 870API 870API 870API 870API Wireless Indoor Asset Protection Device Wireless Indoor Asset Protection Device Wireless Indoor Asset Protection Device Wireless Indoor Asset Protection Device INSTALLATION AND SETUP GUIDE QUICK INSTALLATION Step 1.
  • Page 2 5870API is for use on objects that do not move Please refer to the control panel’s installation frequently or vibrate. Mounting the sensor near instructions for details on device enrollment.
  • Page 3 REPLACING THE BATTERY MOUNTING NOTES 5870API is powered by a 3-volt lithium battery. If the 3M VHB double –sided tape can be used on the battery voltage gets too low, the device sends a low battery following surfaces: acrylic, polycarbonate, coated signal to the control panel.
  • Page 4: Warranty Information

    UL APPROVED COMPATIBLE CONTROL PANELS The 5870API is compatible with the following commercial control panel families: Vista-10P/10PCN/10PSIA, Vista-10SE/10SEADT/10ROSE, Vista-10P1PACK, Vista-10PASE Vista-15/15CN, Vista- 15P/15PCN/ PSIA, Vista-15PMT, Vista-20BAY, Vista-20P/20PCN/20PBAY, Vista-20MT, Vista-20PS/20PSCN, Vista-20PSIA, Vista-20SE/-20HWSE, Vista-20AMT3, Vista-40, Vista-48C/48D, Vista-50P/50PADT, Vista-50PEN/50PENADT, Vista- 128B,Vista-128BP/128BPADT, Vista-128FBP, Vista-250BP, Vista-250FBP, FA130CP/130CP-CN/130CPSIA, FA148C/148C-...