Bosch Greentherm T9800 SEC 199 Installation And Operating Instructions Manual page 4

Indoor residential and commercial tankless water heaters
Hide thumbs Also See for Greentherm T9800 SEC 199:
Table of Contents

Advertisement

4 | Key to symbols and safety instructions
Insufficient ventilation may cause toxic flue gas to escape.
Risk of poisoning.
▶ Never close off or reduce the size of the air intake and outlet
openings.
▶ The appliance must not be operated until any obstructions
have been removed.
▶ Inform the customer of the problem and the associated
dangers.
Danger from escaping flue gases
▶ Ensure all vent pipes and chimneys are not damaged or
blocked.
▶ Connect only one appliance to each vent system or
chimney liner, except for cascading installation.
▶ The venting system piping must not feed into another air
extraction duct.
▶ Do not route the flue system piping through or inside
another air extraction duct.
Danger of explosion of flammable gases
▶ Work on gas components may only be carried out by a
trained and certified installer.
▶ Installation, gas and flue connection, initial commissioning,
electrical connections and annual maintenance must only
be carried out by a trained and certified installer.
Combustion air
▶ Keep the combustion air free of corrosive substances
(halogenated hydrocarbons that contain chlorine or
fluorine compounds).
Never shut off safety valves!
▶ Water may escape from the safety valve at any time when
the water is being heated.
Inspection/maintenance
▶ Servicing and repairs may only be carried out by a trained
and certified installer.
▶ Immediately correct all faults to prevent system damage.
▶ Use only Bosch spare parts!
Instruct the customer
▶ Explain to the customer how the appliance works and how
to operate it.
▶ Inform the customer that he/she must not carry out any
alterations or repairs.
6 720 816 815 (2018/08)
Danger from electric shock
▶ Ensure that only an authorized contractor performs
electrical work.
▶ Before performing electrical work, disconnect the power
and secure the unit against unintentional reconnection.
▶ Ensure the system has been disconnected from the power
supply.
Risk of scalding at the hot water fixture
▶ When the water heater is in operation, temperatures in
excess of 120 °F (49 °C) can occur. To limit the
temperature at the tap, install a thermostatic DHW mixing
valve.
▶ Water heated for washing the laundry, dishes and for other
cleaning purposes can cause scalding and permanent
injuries.
▶ Children, disable and elderly are at highest risk of being
scalded. Never leave such individuals in the tub or shower
unattended under any circumstances. Children must not
be allowed to operate hot water faucets themselves.
▶ If the building has occupants in the above groups who
operate hot water faucets, or state laws / local ordinances
stipulate specific water temperatures, take the following
precautions:
– Use the lowest possible temperature setting.
– To prevent scalding, install a tempering device, such as
an automatic mixing valve, at hot water tap or water
heater. Select and install the automatic mixing valve in
accordance with the valve manufacturer's
recommendations and instructions.
▶ Water exiting from drain valves can be extremely hot. To
avoid injuries:
– Check that all connections are tight.
– Direct exiting water away from people.
▶ Measures must be taken to protect against excessive
temperature and pressure! Installation of a T&P safety
valve is required.
To protect against corrosion and ensure compliance with the
rules for electrical safety, observe the following points:
▶ Use metal fittings for potable water heating systems with
plastic piping.
▶ Use only original accessories from the manufacturer.
▶ When installation of the water heater is complete, inspect
and confirm proper ground conductor.
Maintenance
Customers are advised to:
▶ Inspect and maintain the water heater on a yearly basis.
Service as needed. See chapter 7.1.
▶ Use only genuine spare parts.
Greentherm T9800 SE 160/199 | SEC 199

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greentherm t9800 se 160Greentherm t9800 se 199Greentherm t9800 seGreentherm t9800 sec

Table of Contents