Pfaff Series 580 Supplement To The Instruction Manual page 24

Table of Contents

Advertisement

Parameter input
* = These parameters remain unchanged when the set parameter values are reset,
24
7
797
Hardware-test
798
User level
0 = user level A
1 = mechanic level B
11 = service level C
799* Selected machine class(see Table of
machine types on Page 18)
8
800* Motor rotating direction when looking
at V-belt pulley
1= anti-clockwise, 0 = clockwise
801
Reversing angle at end of seam
814
Change-over of positioning method
1 = Ramp braking in target position
2 = Max. braking at positioning speed
and wait till target position is
reached.
815
Motor starting method after mains on
1 = sinus method,
2 = impulse method
880
Max. starting current [A]
881
Adjust positioning behaviour of motor
to the machine to avoid vibrations
884
Proportional amplifi cation of speed
control of sewing motor
885
Integral amplifi cation of speed control
of sewing motor
886
Proportional amplifi cation of positioning
controller(sewing motor)
887
Differential amplifi cation of positioning
controller(sewing motor)
see Chapter 7.01 Reset / Cold start.
1, 2, 3, 4, 5
C
ON - OFF
1, 2, 3, 4, 5
B
0 - 20
1
C
1 - 5
2
C
1 - 5
3
C
1 - 5
4
C
1 - 5
5
C
1 - 5
1, 2
C
0 - 1
3, 4, 5
C
0 - 1
1, 2, 3, 4, 5
B
10 - 212
1, 2, 3, 4, 5
C
1 - 2
1, 2, 3, 4, 5
C
1 - 2
1, 2, 3, 4, 5
C
1 - 10
1, 2, 3, 4, 5
C
3 - 24
1, 2, 3, 4, 5
B
3 - 24
1, 2, 3, 4, 5
C
10 - 80
1, 2, 3, 4, 5
C
1 - 15
1, 2, 3, 4, 5
C
1 - 15
OFF
0
1
2
3
4
5
0
1
32
2
1
8
10
10
50
8
8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Series 1180Series 3701Series 5480

Table of Contents