2.4.Setting sheet
The Setting sheet (Fig. 5) allows you to make settings necessary for communications
between the inverter and the computer and to write and read related parameters.
2
3
4
② Communication setting
'COM Port': Specify the COM port number of the computer.
'Baud rate': Specify the baud rate (F800) of the inverter.
'Parity': Specify the parity (F801) of the inverter.
'Inverter number': Specify the number (F802) assigned to the inverter.
Since PCT001Z-E uses the Toshiba inverter protocol ASCII mode, only a number
between 0 and 99 can be assigned to an inverter.
*1 If you select a parameter other than parameters set for the inverter or the computer
connected to it, an error may occur during communication.
Fig. 5 Setting sheet
*1
Fig. 6 Communication setting
5