ADC Adtemp 429 User Manual

ADC Adtemp 429 User Manual

Non-contact thermometer

Advertisement

Non Contact
Thermometer
Model 429
User's Manual
PLEASE NOTE:
THIS MEDICAL INSTRUMENT MUST BE
USED ACCORDING TO INSTRUCTIONS
TO ENSURE ACCURATE READINGS.
Questions?
Call ADC toll free at 1-800-232-2670

Advertisement

Table of Contents
loading

Summary of Contents for ADC Adtemp 429

  • Page 1 Non Contact Thermometer Model 429 User’s Manual PLEASE NOTE: THIS MEDICAL INSTRUMENT MUST BE USED ACCORDING TO INSTRUCTIONS TO ENSURE ACCURATE READINGS. Questions? Call ADC toll free at 1-800-232-2670...
  • Page 2 You'll quickly appreciate the results, for you now own one of the finest Non-Contact thermometers that money can buy. With proper care and maintenance, your ADC ® Adtemp thermometer is sure to provide you with many years of dependable service.
  • Page 3: Table Of Contents

    Adtemp 429 - Instruction Manual Table of Contents . Symbols ........4-5 2.
  • Page 4: Symbols

    1. Symbols Documentation Symbols t^okfkdW The warning statements in this manual identify conditions or practices that could lead to illness, injury, or death. `^rqflkW The caution statements in this manual identify conditions or practices that could result in damage to the equipment or other property, or loss of data. Consult instructions for use (IFU).
  • Page 5: Introduction / Intended Use

    Miscellaneous Symbols Type BF applied part Battery Level Indications Low battery (thermometer can still be used) Low battery- the batteries must be replaced before further operation...
  • Page 6 Warning: If the accuracy of any measurement is in question or the use of this thermometer is not appropriate due to patient condition, check the patient's temperature with an alternate method and then check to verify the device is functioning properly by comparing it against a calibrated reference device.
  • Page 7 Caution: Stop using this device if it operates erratically or if the display malfunctions. Caution: Contact ADC or your local ADC representative for any assistance with this device. Refer to the warranty section of this manual for contact details. Caution: Allow 30 minutes for both patient and thermometer to become accustomed to existing environmental conditions prior to measurement.
  • Page 8: Using The Thermometer

    4. Using the Thermometer 4a. Controls and Features 4b. LED Screen/Display 4c.Selecting a Scan Mode With the power on, press the Human/Object button to switch between scan modes. There are 4 modes available, including Human, Object, Human/Night, and Object/Night mode (in order). The thermometer’s volume will be muted in both Human/Night mode as well as Object/Night mode, and the Moon symbol will appear on the LCD in both Night modes.
  • Page 9: 4D.changing The Temperature Scale

    Note: Each press of the Human/Object button is accompanied by a beep sound to confirm that the setting is activated. (excluding Night modes) 4d.Changing the Temperature Scale The Adtemp™ 429 Non Contact Thermometer can display readings in either Fahrenheit (F) or Celsius (C). The default temperature scale is Fahrenheit.
  • Page 10 Note: If the patient’s skin is covered with hair, sweat, or dirt, clean the area and wait 10 minutes before taking a measurement. Note: Ensure that the thermometer is held firmly during measurement and that the patient does not move until the measurement is complete. Patient movement can impact the measurement.
  • Page 11: Memory Function

    6.Memory Function The unit retains the last 30 readings. To recall previous readings: 1. Press the Measure button to power the unit on. 2. Briefly press and release the Memory button then press again to display the last measurement accompanied by the symbol.
  • Page 12: Troubleshooting/Error Messages

    In the event of a repeated The temperature measured is lower than: error message, contact your 1. Human Mode : retailer or ADC’s Customer 50°F (10°C) Service line at: 2. Object Mode : 1-800-ADC-2670 32°F (0°C) Operate the thermometer...
  • Page 13: 8B. Cleaning And Disinfecting

    If the batteries are completely depleted, “Lo” will be displayed along with the low battery symbol. 1. Use a Phillips head screwdriver to loosen battery cover screw. Remove cover. 2. Remove the batteries. 3. Insert two AAA (or equivalent) batteries, correctly positioned with positive “+”...
  • Page 14: Calibration Testing

    Note that ADC is not responsible for validating the cleaning or disinfection protocols used on this device outside of ADC’s manufacturing site. You should determine the requirements for personnel, equipment, and materials necessary to achieve your desired disinfection levels and may need to employ routine monitoring of your disinfection protocols within your facility.
  • Page 15: Technical Specifications

    11. Technical Specifications Type Non-Contact infrared thermometer Model no. 429 122.0° F Measuring Range: 50° C Human Mode: 50.0°F ~ 122.0°F 50° F 10° C (10°C ~ 50°C) 212.0° F 100° C Object Mode: 32.0°F ~ 212.0°F (0°C ~ 100°C) 32.0°...
  • Page 16: Standards

    12. Standards ASTM 1965-98 EN 12470-5:2003 MDD (93/42/EEC) Annex II 13. Guidance and Manufacturer's Declaration The 429 IR Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the 429 Thermometer should assure that it is used in such an environment.
  • Page 17 dìáÇ~åÅÉ ~åÇ j~åìÑ~ÅíìêÉêDë aÉÅä~ê~íáçå bäÉÅíêçã~ÖåÉíáÅ Éãáëëáçåë The 429 IR Thermometer is intended for use in the electromagnetic environment specified below. The customer or the user of the 429 IR Thermometer should as- sure that it is used in such an environment. bäÉÅíêçåáÅ...
  • Page 18: Warranty

    oÉÅçããÉåÇÉÇ ëÉé~ê~íáçå Çáëí~åÅÉë ÄÉíïÉÉå éçêí~ÄäÉ ~åÇ ãçÄáäÉ oc ÅçããìåáÅ~íáçåë ÉèìáéãÉåí ~åÇ íÜÉ QOV fo qÜÉêãçãÉíÉê The 429 IR Thermometer is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the 429 IR Thermometer can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the 429 IR Thermometer as recommended below, according to the...
  • Page 19: Contact Information

    15. Contact Information qç=êÉÖáëíÉê=óçìê=éêçÇìÅí=îáëáí=ìë=~í ïïïK~ÇÅíçÇ~óKÅçãLêÉÖáëíÉê qÜáë=ã~åì~ä=áë=~î~áä~ÄäÉ=çåäáåÉ=áå=~ î~êáÉíó=çÑ=ä~åÖì~ÖÉëI Ñçääçï=íÜÉ=äáåâë=Ñçê=ä~åÖì~ÖÉ=çéíáçåëK ïïïK~ÇÅíçÇ~óKÅçãLÅ~êÉ...
  • Page 20 ® AViTA Corporation Distributed by: American Diagnostic Corporation 9F, No.78, Sec.1, Kwang-Fu Rd., 55 Commerce Drive, San-Chung District, Hauppauge, New York 11788 24158 New Taipei City, Inspected in the U.S.A. Taiwan Made in China tel: 631-273-9600, 1-800-232-2670 Wellkang Ltd., EC REP fax: 631-273-9659 Suite B, 29 Harley Street, LONDON W1G 9QR,...

Table of Contents