[9] USER PROGRAM
The factory setting can be changed according to the operating conditions.

1. User program functions

Function
Auto clear
Pre-heat
Auto power shut off passing
time
Stream feeding mode (with
SPF/R-SPF installed)
*1: The power consumption in pre-heat, auto power shut off depends on the operating conditions.
2. Setting change procedure
Example: Changing the time for operating the auto clear function
(from 60 sec to 120 sec)
1) Press and hold the density adjustment key
setting.
When
lamps start blinking at the same time,
and the copy quantity display shows "--" the digit of 10 blinking.
2) Select the function code with the copy quantity set key.
The code of the selected function is displayed (blinking) on the
digits of 10 and 100.
For auto clear, select 1.
Select the suitable code according to the table below.
User program setting contents
Function
Auto clear
Pre-heat
Auto power shut off passing
time (*1)
Auto power shut off function
setting (*1)
∗: Factory setting
*1: With the auto power shut off canceled (function code "5", set
code "0", auto power shut off time setting code "3"), the mode
enters the auto power shut off setting mode automatically.
When a certain time is passed after completion of the machine operation, the mode is returned to
the initial state automatically. The time to return to the initial state can be set in the range of 30 ~
120 sec by the unit of 30 sec. This function can be canceled.
When the machine is left unused with the power ON, the power consumption level is
automatically lowered to about 60Wh (*1). The time to operate this function can be set in the
range of 30 sec ~ 120 sec by the unit of 30 sec. This function can be canceled.
When this function operates, the pre-heat lamp on the operation panel lights up.
To cancel the pre-heat state, press any key on the operation panel.
(When the START key is pressed, pre-heat is canceled and copying is started.)
This function is canceled with the document is set or the tray is pulled out.
When the machine is left unused with the power ON, the power consumption is automatically
lowered to about 4.8Wh (*1). The time to operate this function can be set in the range of 30 min
to 240 min. When this function operates, all the lamps except for the pre-heat lamp turn off.
To cancel the auto power shut off state, press the START key.
The auto power shut off function can be canceled.
for 5 sec to start
Function code
Setting code
1
0 (Cancel)
1 (30 sec)
∗2 (60 sec)
3 (90 se)
4 (120 sec)
2
0(Cancel)
1 (30 sec)
2 (60 sec)
∗3 (90 sec)
4 (120 sec)
∗1 (30 sec)
3
2 (to sec)
3 (90 sec)
4 (120 sec)
5 (240 sec)
5
0 (Cancel)
∗1 (Setting)
Outline
The selected key number is displayed on the digit of 1 on the
copy quantity display.
Cancel: When a wrong number is entered, press the clear key and
enter the correct number.
3) Press the START key.
The selected function code is changed from blinking to lighting.
The currently set code is displayed (blinking) on the digit of 1.
4) Select the setting code with the copy quantity set key.
To set to "90 sec", select
Refer to the setting code list in "User Program setting content"
for setting.
Cancel: When a wrong function code is selected, press the clear key
and repeat procedures from 2).
5) Press the START key,
The selected setting code is changed from blinking to lighting.
The setting is done with the above.
Memo: To set another function, press the clear key and repeat from
procedure 2).
6) Press the density adjustment key
The lamps
tity display returns to the normal display.
9 – 1
AL-1610
Default
60 sec
90 sec
30 min
Limited
3
.
to complete setting.
are turned off and the copy quan-

Advertisement