36
PROGRAMMING MODE
1.
Pressing the Start button cycles to the next test function.
Number of times
the Start
button is pressed
None
Check the version and code of
machine.
■ ELECTRIC COIN TYPE : AU:OE
1 time
■ ELECTRIC OPL TYPE : CA:PE
■ GAS COIN TYPE : AU:Og
■ GAS OPL TYPE : CA:Pg
2 time
PDA CHECK
3 time
Motor runs.
■ ELECTRIC TYPE: Heater runs.
4 time
■ GAS TYPE: GAS valve runs.
■ ELECTRIC TYPE: Heater runs.
5 time
■ GAS TYPE: GAS valve runs.
LED & KEY CHECK
Press High Temp. button.
6 time
Press Med Temp. button.
Press Low Temp. button.
Press No Heat button
7 time
Test ends.
Door switch
During check, if the
(Motor & Heater Off, Buzzer beeps
door is open.
seven times)
During check, if the
Test goes back at step 2.
door is closed
(Motor on & Heater Off )
NOTE
During LqC1 test, if no buttons are pressed for 4 minutes, machine will be turned off automatically.
Do not use
.
Checking point
Motor + Heater 1 (2250W)
Motor + Valve
Motor + Heater 1 (2250W) + Heater
2 (2250W)
Motor+Valve
Display
LqC 1
Version and code of machine (All LED on)
COIN machine displays AU:OE or AU:Og and gU:XX
alternately. OPL machine displays CA:PE or CA:Pg and
gU:XX alternately. XX is the version number
Ir--
Measured moisture value (70~239)
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
Current temperature (5~70)
(Displays the temperature inside the drum in ° Celsius.)
Version and code of machine
LqC1
dE
(The door is open. Please close the door completely)
Measured moisture value (70~239)