The VX-44d/-55d uses a Cermax® Xenon lamp to deliver its high brightness. The lamp
should be replaced when it reaches the end of its life (typically 1000 hours), or sooner if a
noticeable degradation in brightness occurs. When you replace a lamp, you should
replace the filters as well.
Keep track of the number of hours the lamp has been in use and be aware of any changes
to brightness. These indicators will help you effectively maintain operation of the projector.
To find out how long the currently-installed lamp has been in service, select Lamp Hours
from the DHD Controller Installation menu (available by selecting Service -> Display
Device -> Configure -> Installation, in sequence).
For lamp or filter replacement, please contact your nearest Runco authorized
service center or Runco dealer. Do not attempt to replace the lamp yourself!
1. Turn off the projector and unplug the power cord. Allow the projector to cool down for
approximately 45 minutes prior to removing the lamp assembly for replacement.
2. Loosen the four rear Lamp Cover screws (see Figure 5-1) and remove the cover.
Figure 5-1. Removing the Lamp Door
3. Pull (out) and turn the lamp lock lever, which is located to the left of the lamp module,
a quarter turn counterclockwise to the "unlock" position (Figure 5-2).
Figure 5-2. Unlocking the Lamp
Runco VX-44d/-55d Owner's Operating Manual

5. Maintenance and Troubleshooting

Lamp cover - 4 screws