Troubleshooting Guide
ERROR
DISPLAYED
PRIORITY
ERROR #
2
E30
2
E31
2
E32
2
E33
2
E34
2
E40
2
E41
2
E42
2
E43
2
E44
2
E45
2
E50
2
E51
2
E52
#821684 - Revision B - March, 2013
Induction Cooktop (CTI) Series
Induction Cooktop (CTI) Series
ERROR
CONDITION
Generator 1:
Effected burner is not
Burner (F,FR,FC)
available.
'ON LED' Failure
Generator 1:
Burner (R,RR,RC)
'ON LED' Failure
Generator 2:
Burner (RL) 'ON
LED' Failure
Generator 2:
Burner (FL) 'ON
LED' Failure
Generator 3:
Burner (RR) 'ON
LED' Failure
Generator 1:
The effected burner will
Burner (R,RR,RC)
shutdown.
sensor shorted.
Generator 2:
Burner (RL) sensor
shorted.
Generator 3:
Burner (RR) sen-
sor shorted.
Generator 1:
The effected burner will
Burner (R,RR,RC)
shutdown.
sensor open.
Generator 2:
Burner (RL) sensor
open.
Generator 3:
Burner (RR) sen-
sor open.
Generator 1:
The effected burner will
Open heat sink
shutdown.
thermistor.
Generator : Open
heat sink thermis-
tor.
Generator 3:
Open heat sink
thermistor.
POSSIBLE SOURCE(S) OF
NOTES
FAILURE / ACTION REQUIRED
LED board failure.
Action: Perform LED test #1 and if all
LEDs work, reset error.
Action: If one of the LEDs fails to illuminate
change the Glass Assy.
Induction generator failure.
Action: Change affected generator board.
Induction generator failure.
Action: Change affected generator board.
1. Induction generator failure.
Action: Perform Heatsink test #4 and if
appears ok, reset error and test operation
2. If error returns.
Action: Change affected generator board.