Thank you for selecting Aiphone for your communication needs.
Please make sure to read this manual for safe and correct use of the system, and keep it in a safe place for future reference.
*
Please note that images and illustrations depicted in this manual may differ from the actual product.
NIM system
OPERATION MANUAL
*
The illustration shows the
master station, 40-call
(NIM-40B).

Advertisement

Table of Contents
loading

Summary of Contents for Aiphone NIM-20B

  • Page 1 40-call (NIM-40B). Thank you for selecting Aiphone for your communication needs. Please make sure to read this manual for safe and correct use of the system, and keep it in a safe place for future reference. Please note that images and illustrations depicted in this manual may differ from the actual product.
  • Page 2: Table Of Contents

    Contents Introduction ........ 3 USING THE SYSTEM (AT A SUB STATION) ........16 Precautions ......... 3 WARNING ........... 3 Answering a call ....... 16 CAUTION ..........3 Calling the master station ..16 GENERAL PRECAUTIONS ....3 NOTICES ..........3 APPENDIX ........
  • Page 3: Introduction

    Electric shock could result. 2. In areas where broadcasting station antennas are close by, this 4. For power supply, use Aiphone power supply model specifi ed system may be affected by radio frequency interference. for use with system. If non-specifi ed product is used, fi re or 3.
  • Page 4: Getting Started

    The following is a system confi guration example. You can select needed equipment to confi gure a system to meet your application needs. • Master station, Master station, 40-call (NIM-40B) 20-call (NIM-20B) • Master station, 60-call /80-call : Special order product.
  • Page 5 Maximum number of stations in a single system The maximum number of sub stations differs depending on the master station model. Master station Sub station (Qty) Personal computer (Qty) Model NIM-20B NIM-40B Master station, 60-call Master station, 80-call : Special order product. N/A in North America.
  • Page 6: Part Names

    Master station, 80-call Supports up to 80 sub stations. : Special order product. N/A in North America. Master station, 40-call (NIM-40B) Master station, 20-call (NIM-20B) Room plate (→P. 7) Station selector and indicator Nameplate (→P. 7) Call-in (red)/talk (green) indicator...
  • Page 7: Sub Station

    ■ How to use the magnetic room and name plates Room plate (included) Nameplate (included) Write information (e.g. room Write information (e.g. name) on number) on the plate in the the plate. corresponding positions. Attach the plate on the Attach the plate on the corresponding position.
  • Page 8: Call Button, Wall Jack

    Ceiling speaker (NI-LB) Ceiling microphone (NI-SB) Call indicator (red) Microphone Speaker Sub station, fl ush mount (NI-JA) Sub station, surface mount (NI-BA) Speaker Microphone Call indicator (red) Call indicator (red) Microphone Call button Call button Speaker Call button, wall jack Bedside call Wall jack for Wall jack with microphone...
  • Page 9: Corridor Light, Reset Button

    Call button (NIR-6) Bathroom call button Bathroom call button (NIR-7W) with pull cord (NIR-7HW) Call indicator Call indicator (red) (red) Call button CALLbutton CALL button CALL CALL Pull cord: Approx. 550mm (21-5/8") Pull cord Initiates a call. * The pull cord length can be adjusted as follows.
  • Page 10: Software

    Corridor light with nameplates, 4 names (NIR-34) Lamp (red) Room number plate (See below.) Individual user display Individual call indicator (red) Nameplate (See below.) Lights up while receiving a call from the corresponding sub station. Magnetic plate display panel Magnetic plates can be attached here. * Magnetic plates are not included.
  • Page 11: Using The System (At The Master Station)

    USING THE SYSTEM (AT THE MASTER STATION) Answering a call When receiving a single call • The ringtone sounds. • The call-in/talk indicator for the calling station blinks red. Station 6 • If a corridor light is installed at the Station 7 sub station, it also lights up.
  • Page 12: When Receiving Multiple Calls

    When receiving multiple calls • The ringtone sounds. • The call-in/talk indicators for the calling stations blink red. Up to 10 calls are received on the master station at the same time. The 11th and subsequent calls are cancelled. The call indicators on the stations of the 6th to 10th calls and the Station 6 corresponding corridor lights do not light up.
  • Page 13: Calling Sub Stations

    Calling sub stations Calling a single sub station Press the station selector button for the sub station to be called. The corresponding call-in/talk indicator lights up green. NIM system The following operations can be performed. ■ Talking with handset ■ Talking in Push-to-Talk mode Pick up the handset and talk with the user of the Press and begin talking.
  • Page 14: Paging

    Paging You can page all stations or only the selected stations simultaneously. [When paging all stations] Press ALL CALL Lights up red. NIM system ■ Speaking with handset ■ Speaking in Push-to-Talk mode , and begin speaking. Pick up the handset and begin speaking Press and hold TALK Lights up red.
  • Page 15: Adjusting Volume

    [When paging only the selected stations (Group Call)] Press the station selector button(s) The call-in/talk indicator(s) for the selected station(s) for the sub station(s) to be called. blink(s) green. Up to 5 stations can be selected. NIM system ■ Speaking with handset ■...
  • Page 16: Using The System (At A Sub Station)

    USING THE SYSTEM (AT A SUB STATION) Answering a call Calling the master station When receiving a call from the master station; Press the call button A pretone is heard from the speaker, and the caller speaks. The type of call button differs depending on the equipment used in your application.
  • Page 17: Appendix

    80-call Material 30-11/16" (W) x 9-1/16" (H) x 5-1/2" (D) Main unit: Plastic Front panel: Silver (stainless steel, vertical NIM-20B Approx. 3.4 kg (7.48 lbs.) Color hair-line processed) NIM-40B Approx. 4.8 kg (10.56 lbs.) Weight 120 (W) x 120 (H) x 53.5 (D) mm 60-call Approx.
  • Page 18 Ceiling speaker (NI-LB) Wall jack for NIR-8 (NIR-1) Power source Supplied from the master station Ambient temperature 0 - 40°C (+32°F - +104°F) Ambient temperature 0 - 40°C (+32°F - +104°F) Mounting Wall (fl ush)-mount Mounting Flush-mount on the ceiling Electrical box 1-gang box Material...
  • Page 19 Bathroom call button with pull cord (NIR-7HW) Corridor light with reset button (NIR-42) Power source Supplied from the master station Power source Supplied from the master station Ambient temperature 0 - 40°C (+32°F - +104°F) Ambient temperature 0 - 40°C (+32°F - +104°F) Mounting Wall (fl...
  • Page 20: Warranty

    fi nal decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty. This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, power surge, or to use in violation of instructions furnished, nor extended to units which have been repaired or altered outside of the factory.