Summary of Contents for Worcester GREENSTAR SYSTEM FILTER

  • Page 1 INSTALLATION & SERVICING INSTRUCTIONS GREENSTAR SYSTEM FILTER FOR SEALED & OPEN VENT CENTRAL HEATING SYSTEMS WITH 22MM CENTRAL HEATING PIPES UK/IE...
  • Page 2: Table Of Contents

    CONTENTS ADDITIONAL SYMBOLS CONTENTS Symbol Meaning a reference number to identify/refer to a part or item Symbols and safety precautions 2 Explanation of symbols 2 a numbered step in an action sequence Safety precautions 2 ▶ a step in an action sequence ...
  • Page 3: Standard Package

    Worcester, Bosch Technical Support. GENERAL INFORMATION Greenstar system filter should only be installed The Greenstar system filter is suitable for 22mm pipe central by a competent person. If in any doubt, consult heating systems and can be fitted anywhere on the main a qualified heating engineer.
  • Page 4: Installation

    INSTALLATION Fig. 7 System filter installation 4. Tighten the compression fittings firmly, but do not over tighten. Fig. 5 Dimensions continued INSTALLATION ▶ Drain the central heating or isolate feed and expansion tank and release the system pressure. 1. Measure, mark and cut out a 70mm section of pipe. 2.
  • Page 5: Servicing

    SERVICING Always service the filter before leaving the premises. The two large spanners should be left with the customer. SERVICING NOTICE: Before commencing any servicing work, turn off the electrical supply to the boiler. 1. Turn both isolation valves to the marked OFF position. Fig.
  • Page 6: Chemical Dosing

    CHEMICAL DOSING Fig. 13 Fig. 15 7. Using a suitable spanner open the isolation valves (If the ▶ Attach the chemical adaptor and feed in the chemical. filter is used on a sealed system, recharge the system to 2. Wait five seconds before removing the adaptor. correct working pressure).
  • Page 7 It is recommended that your system filter is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider Before completing the appropriate Service Record Below, please ensure you have carried out the service as described in the servicing section of the manual. Always use Worcester approved spare parts. Service 1 Date: Service 6...
  • Page 8 LITERATURE: 0844 892 9800 TRAINING: 01905 752526 SALES: 01905 752640 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0844 892 9900 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 6 720 803 839 (2012/11)