ON
10. Fully / Semi automatic mode
OFF
(for IR-PD-DIM-HKLfunctions see page 1)
The system switches over when the "Light" push-button is
open (see remote control functions, page 1).
Each time a push-button is pressed, the current operating
mode is indicated by the red LED:
Lit for 3 sec. = Fully automatic mode
Flashes for 3 sec. = Semi-automatic mode
Fully automatic operation
In this operating mode, the lighting switches automatically on
and off for increased comfort, depending on presence and
brightness.
Semiautomatic operation
(Semiautomatic can only be activated via the remote control!)
In this operating condition, in order to gain increasedsav-
ings, the lighting is energized only after being manually
switched on. Switch-off takes place automatically.The
semiautomatic mode basically behaves like the fully
automatic. However, the difference is that switching-on must
always be carried out manually!
As many (closer-contact) buttons as desired can be wired in
parallel on the "S" button input (ON/OFF Dimm).
11. Manual Dimming – Preset /User
(for IR-PD-DIM-HKLfunctions see page 1)
You can dim manually by pressing the push button for
a long time (> 2 sec). When the button is released,
the current dimming value is retained. Upon renewed
dimming, the dimming direction is reversed.
PRESET – the luminance set point is set during start-up
operation by the installer and remains unchanged.
The luminance set- point configured through manual
dimming is only applied for the time being.
Caution:
The constant light regulation is now deactivated!
The currently set artificial light is retained independent
of the ambient/daylight brightness!
After switching off and then back on, the originally set
max
luminance set-point is reset = constant light regulation
is activated.
ON
USER – can only be activated via the remote control!
The luminance set-point is changed upon each manual
max
OFF
dimming and re-adjusted by the user (Conformation
through relay clicking!)
The constant light regulation remains activated!
ON
12. Manual Switching
OFF
The light will remain switched on or off, as movements are
detected in the area. After the last detected movement the
light will be off for the duration of the set-up time. The device
will then return independently to the Operation mode (Full or
Semi-automatic).
13. Range
2,50 m
3
1
1
quer zum Melder gehen
Walking across
2
frontal zum Melder gehen
Walking towards
3
Unterkriechschutz
Seated

14. Wiring diagrams

Standard mode with master-DIM-HVAC-occupancy detectors
L
N
T1
T2
S
Master
M1 = HVAC-Function
optional
T1 = NO Taster for Light-Channel
T2 = NO Taster for HVAC-Channel
Slave to the extension of coverage
15. Connections
L
N
N
E1
L
1-10 V
+
EVG
50
1500
Lux
Lux
50
1500
Lux
Lux
16. Manual switching HVAC-Channel
230VAC for 0.1 - 1 second on the slave port R
Lay on the slave port R for 0.1 - 1 second to 230VAC,is this
like a key signal for the HVAC channel interpreted.
17. Article / Part nr. / Accessory
Type
PD4-M-DIM-HVAC (Master)
PD4-S (Slave)
LUXOMAT
Remote control
®
IR-PD-DIM-HKL(incl. wall bracket)
Accessory:
BSK Ball basket guard
2
Occupancy detectors – Covering IP23
18. Exclude sources of interference
In case the sensing area of the LUXOMAT
is too large or areas are being covered that should not
be monitorerd, the range can be reduced or limited
through use of the enclosed masking clips
N
L
E1
1-10 V EB
M1
+
-
R
N
L
NO
NO
L´1
+
-
R
N
C1
C1
HVAC
HVAC
Slave
M1
T2
T1
– + R
L
L' NO
S N
NO
PD4-M-DIM-HVAC-FC
SM
FC
FM
92507
92142
92254
92163
92114
92199
92206
e
PD4-M-DIM-HVAC
®
19. Technical data PD4-M-DIM-HVAC
Sensor and power supply in one case for onwall-, ceiling- and
flushmounting
Power supply:
Power consumption:
Ambient temperature:
Degree of protection/class:
Settings:
Light values remote control: 50 - 1500 Lux
Extension of the detection area: with Slaves
Area of coverage:
Range of coverage Ø H 2,50 m / T = 18°C:
L
Recommended height for mounting: 2 - 3 m
Light measurement:
Lux values potentiometers:
• Channel 1 for light-connection
Type of contact:
Contact load:
DIM-Outputs:
Max. no. of series-connected electronic ballasts: max. 50 electronic
ballasts by one single supply with max. 100 m cable run and a
conductor cross-section of 0.75 mm²
Time-settings:
• Channel 2 for control devices (only reacts on motion)
Contact load:
Time-settings:
Dimensions H x Ø [mm]
Visible portion when built into ceiling: 38 x 98 mm
Technical data PD4-Slave
Power supply:
R
Impulse output:
Slave
Impulse duration:
Dimensions:
Declaration of Conformity: The product complies with the low
voltage recommendation 2006/95/EC and the EMV recommenda-
tion 2004/108/EC.
WE RECOMMEND THAT BEFORE DIMMING OF THE CONNECTED
LIGHTS A 100H BURN IN (T5 TUBES OR 80 HOURS FOR T8 TUBES )
FUNCTION TA kES PLACE .
THE LIFESPAN OF THE LAMPS CAN BE REDUCED IF THE BURN IN
DOES NOT TA kE PLACE .
20. LED-functional indicators, fault-finding
The functional indicators in the case of the LUXOMAT
PD4-M-DIM-HVAC (red and green LED's)
Red LED indicating self-checking mode (over a period of 60
seconds following mains'-supply lock-on)
Flashing at intervals of 1 second
EEPROM/memory empty
Flashing rapidly
EEPROM/memory contains information
Red LED as an indicator of status
Flashing irregularly
Movements are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
Flashing extremely rapidly
Too bright / Too dark / Undefined
Red LED as an acknowledgement of receipt for commands from
the remote control
Illuminated for 2 seconds
Signal validly received
Illuminated for 0.5 seconds
Not-accepted command, detector blocked
Flashing extremely rapidly
Not-accepted command, occurs, for example, when an attempt
is made to input twilight-value are too bright or too dark
Green LED as an acknowledgement of receipt for commands from
the remote control
Lights up for 3 seconds
Semi automatic or user signal correctly received
Green LED as an indicator of status (only for status
"Permanent protection against sabotage")
Flashing irregularly
Movement are detected within the area of coverage
Flashing regularly
Detector identifies bright, light off
(dependent upon operating mode)
Not illuminated
Detector identifies dark, light on
(dependent upon operating mode)
lluminated for 2 seconds
Signal validly received
(dependent upon operating mode)
White LED
Lights permanently
Semi-automatic active (shines)
Illuminates 4 seconds, then 1 sec off
Semi-automatic and active corridor
Illuminates 1 seconds, then 4 sec off
Only active corridor
230 V~ ±10 %
< 1W
-25 °C to +50 °C
FC IP20 / II
locally and by remote control
circular 360°
seated 6,40m / tangential 24 m /
radial 8 m
Mixed light, daylight + artificial light
10 - 2000 Lux
NOC/with pretravel tungsten
contact
2300 W cos ϕ =1 /
1150 VA cos ϕ = 0,5, µ-Contact
1 x (1 -10 V)
1 - 30 Min. / Test
230 V~, 3 A cos ϕ=1, µ-Contact
5 min. - 120 min. with time delay of
5 min. for follow-up time > 15 min./
Alarm impulse
103 x 98
230 V~ ±10 %
Optocoupler max. 2 W
2 s or 9 s
see above
®