Communication Parameters - LG 42PQ20D-AA Owner's Manual

42pq2 series; 50pq2 series; 42pq6 series; 50pq6 series; 50ps3 series; 60ps4 series; 60ps6 series
Hide thumbs Also See for 42PQ20D-AA:
Table of Contents

Advertisement

Communication Parameters

Baud rate : 9600 bps ( UART )
A
Data length : 8 bits
A
Parity : None
A
Command Reference List
COMMAND
1
01. Power
k
02. Aspect Ratio
k
03. Screen Mute
k
04. Volume Mute
k
05. Volume Control
k
06. Contrast
k
07 . Brightness
k
08. Colour
k
09. Tint
k
10. Sharpness
k
1 1. OSD Select
k
1 2. Remote control lock mode k
1 3. Treble
k
1 4. Bass
k
1 5. Balance
k
1 6. Colour Temperature
k
1 7 . Abnormal Status
k
1 8. ISM Method
j
19. Energy Saving
j
20. Auto Configure
j
21. Tune Command
m
22. Channel Add/Skip
m
23. Key
m
24.Input select (Main)
x
* When setting the 17 ~ 24, a menu does not appear on screen.
* Note: During USB operation such as Dvix or EMF, all com-
mands except Power(ka) and Key(mc) are not executed and
treated as NG.
Stop bit : 1 bit
A
Communication code : ASCII code
A
Use a crossed (reverse) cable.
A
COMMAND
DATA
2
(Hexadecimal)
a
00 ~ 01
c
Refer to p. 1 16
d
Refer to p. 1 16
00 ~ 01
e
f
00 ~ 64
g
00 ~ 64
h
00 ~ 64
00 ~ 64
i
j
00 ~ 64
k
00 ~ 64
l
00 ~ 01
00 ~ 01
m
r
00 ~ 64
s
00 ~ 64
t
00 ~ 64
00 ~ 02
u
z
FF
p
Refer to p. 1 18
q
Refer to p. 1 18
u
01
a
Refer to p. 1 18
b
00 ~ 01
c
Refer to p. 1 19
b
Refer to p. 1 19
Transmission / Receiving Protocol
Transmission
[Command1][Command2][ ][Set ID][ ][Data][Cr]
* [Command 1] : First command to control the TV.
(j, k, m or x)
* [Command 2] : Second command to control the TV.
* [Set ID]
: You can adjust the set ID to choose
desired monitor ID number in option
menu. Adjustment range is 1 ~ 99.
When selecting Set ID '0' , every connect-
ed set is controlled.
Set ID is indicated as decimal (1~99) on
menu and as Hexa decimal (0x0~0x63)
on transmission/receiving protocol.
* [DATA]
: To transmit command data.
Transmit 'FF' data to read status of com-
mand.
* [Cr]
: Carriage Return
ASCII code '0x0D'
* [ ]
: ASCII code 'space (0x20)'
OK Acknowledgement
[Command2][ ][Set ID][ ][OK][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if
the data is data read mode, it indicates present status
data. If the data is data write mode, it returns the
data of the PC computer.
Error Acknowledgement
[Command2][ ][Set ID][ ][NG][Data][x]
* The set transmits ACK (acknowledgement) based on
this format when receiving abnormal data from
non-viable functions or communication errors.
Data 00: Illegal Code
115

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents