Auto Restart Operation; How The Air Conditioner Works - Toshiba RAV-SM307KRTP-A Owner's Manual

Air conditioner (split type) indoor unit high wall type
Hide thumbs Also See for RAV-SM307KRTP-A:
Table of Contents

Advertisement

7

Auto restart operation

This air conditioner is equipped with an Automatic
restarting facility which allows the air conditioner to
resume the set operating conditions in the event of a
supply power shutdown without the use of the remote
controller.
The operation will resume without warning three
minutes after the power is restored.
NOTE
The Auto Restart Operation is not set to work on
shipment from the factory, and so it is necessary to set
it to function as required.
◆ How to set the auto restart
To set the auto restart function, proceed as follows:
The power supply to the unit must be on the function
will not set if the power is off.
To enable the auto restart function, push the
TEMPORARY button continually for more than 3
seconds, less than 10 seconds.
The air conditioner will acknowledge the setting and
beep 2 times (first long, second short sound) and
lamp is flashing 5 seconds (5 Hz). The system will now
restart automatically.
The above auto restart settings can be carried out:
TEMPORARY button
33-EN
1111056504_EN.indd 17
1111056504_EN.indd 17
◆ How to cancel the auto restart
To cancel the auto restart operation, proceed as
follows:
Repeat the setting procedure: the air conditioner will
acknowledge the instruction and beep 2 times (first
long, second short sound).
The air conditioner will now require to be manually
restarted with the remote controller after the main
supply is turned off.
Cancellation is carried out:
TEMPORARY button
– 17 –
8

How the air conditioner works

Automatic operation
• The air conditioner selects and operates in one of the operating modes of cooling, heating or fan only,
depending on the room temperature and setting temperature.
• If the AUTO mode is uncomfortable, the desired conditions can be selected manually.
Hi POWER operation
When the Hi-POWER button is pushed during cooling, heating or AUTO operation, the air conditioner will start the
following operation.
• Cooling operation
Performs the cooling operation at 1 °C lower than the setting temperature.
Only when the fan speed before the Hi POWER operation is not high, the fan speed will be increased.
• Heating operation
Performs the heating operation at 2 °C higher than the setting temperature.
Only when the fan speed before the Hi POWER operation is not high, the fan speed will be increased.
COMFORT SLEEP operation
When the COMFORT SLEEP button is pushed during cooling, heating, or AUTO operation, the air conditioner will
start the OFF timer operation that automatically adjusts the room temperature and the fan speed (expect in DRY,
FAN ONLY and TIMER mode).
You can select the OFF timer time from four durations (1, 3, 5 or 9 hours).
During group control operation, the set temperature and the fan speed are not automatically adjusted. Only off
timer function is activated.
QUIET operation
When the QUIET button is pushed during cooling, heating, or AUTO operation, the air conditioner will start the
following operation.
To operate super low fan speed for quite operation (expect in DRY mode)
DRY operation
This operation is performed when the room temperature is
higher than the set temperature.
The temperature is regulated while dehumidifying by repeated
turning on and off of the cooling operation or fan only
operation.
Increase of using wireless remote controller, the fan speed
display will indicate AUTO and low speed will be used.
Cooling
Fan only
Cooling
Fan only
Cooling
Time
Set temperature
34-EN
9/22/57 BE 3:40 PM
9/22/57 BE 3:40 PM