System Cooling
Fans
Power
Configuration
Max AC input current
Max +12 V output1
current
Max +12 V output2
current
Max +12 V output3
current
Max -12 V output curren 0.5 A (each power supply).
Max +5V Standby outpu
current
Environment
Ambient Temperature
Relative Humidity
Acoustics
Electrostatic Discharge
Safety Compliance
Argentina
Canada
Europe, CE Mark
Germany
International
Nordic Countries
Russia
United States
China
Electromagnetic Capability (Class A) (EMC)
Australia/New Zealand
Canada
Europe, CE Mark
International
Japan
Chassis includes four dual rotor 40 millimeter (mm) hot-swappable redundant system fan
for cooling the hard drives, baseboard and SATA Host Bus Adapter (HBA) cards.
Power supply enclosure contains a 60 mm fan for cooling and runs whenever AC power
applied.
500 W continuous, 1+1 redundant power supplies. Intel Storage System SSR212MA
ships with one 500W power supply.
7.2 Amperes at 110 Vrms, 3.5 A at 220 Vrms (each power supply).
20.0 A (28.6 A max combined).
20.0 A (28.6 A max combined).
20.0 A (28.6 A max combined).
2.0 A
Operating (system): 10 °C to +35 °C, with maximum change not to exceed 10 °C ; non-
operating (system): -40 °C to +70 °C.
Non-operating: 90% @ 35°C non-condensing.
<59 Decibel Average (dBA) (rack-mount) in an idle state in an normal office environment
(23 °C).
15 KV per Intel test specification.
IRAM
UL60950 – CSA (60950 (UL and cUL)
EN60950 (complies with73/23/EEC)
GS License
IEC60950 (CB Report and Certificate)
EMKO-TSE (74-SEC) 207/94
GOST 50377-92
UL– 60950 – CSA 60950 (UL and cUL)
GB4943- CNCA Certification
AS/NZS 3548 (based on CISPR 22)
ICES-003
EN55022; EN55024 & EN61000-3-2;-3-3 (complies with 89/336/EEC)
CISPR 22