Acer X110 Service Manual page 64

Acer projector service manual
Hide thumbs Also See for X110:
Table of Contents

Advertisement

Check pattern
Inspection item
Criteria
3. G Sensor Calibration
(1) Calibration pattern should be in full screen
mode.
(2) Please press "Power", "Left", "Left" and "Menu"
buttons sequentially to get into Service Mode.
(3) Choose "Analog Settings", press "Menu" button
to access "Video Calibration for" correction in
Service Mode. Choose "Exit" to leave the
Service Mode.
- Test signal: 480i
- Test pattern: In focus II or 64 grey RGBW
* After finishing ADC adjustment, check 64 gray
RGBW pattern.
- Color saturation
- There should not have any lack of RGBW. The
color should appear normal and sort in right order.
- Color levels should be sufficient and normal. (the
unidentified color levels on both left and right sides
should not over 8 color levels.)
- Please put the Projector on a horizontal surface.
- Please press "Power", "Left", "Left" and "Menu"
buttons sequentially to get into Service Mode.
- Choose and access "G Sensor Calibration" for
correction.
X1161/X1261/X1161A/X1161N/X110/H5360
InFocus II
/ 64 gray RGBW
Confidential
4-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

H5360X1161X1261Ep720X1161aX1161n