Specifications - Rockford Fosgate 250.2 Operation & Installation

Competition power amplifiers
Hide thumbs Also See for 250.2:
Table of Contents

Advertisement

250.
S
2
PECIFICATIONS
Dynamic Power Rating (IHF-202 Standard) - Measured at 14.4V
Per channel into a 4 load
Per channel into a 2 load
Bridged into a 4 load
Continuous Power Rating (Competition Standard) - Measured at 13.8 Battery Volts
RMS continuous power per channel, both channels driven
into a 4 load from 20 to 20,000Hz with less than
0.05% THD (Total Harmonic Distortion)
RMS continuous power per channel, both channels driven
into a 2
load from 20-20,000Hz, with less than 0.10% THD
RMS continuous power mono, into 4 load
from 20-20,000Hz, with less than 0.1% THD
Common Mode Rejection Ratio (CMRR):
Signal-to-Noise Ratio:
Frequency Response:
Bandwidth:
Damping Factor @ 4 (at output connector):
Slew Rate:
IM Distortion (IHF):
Input Impedance:
Source Unit Compatibility (+15dB Gain Overlap)
Input Sensitivity (+0dB Gain Overlap):
Pass-Thru Output (ref. 1V input @ 1kHz):
B+ Fuse Size: (External to amplifier)
Fuse Type:
Crossover Slope:
Factory Crossover Frequency:
Factory Default Crossover Setting:
Dimensions: (including end caps)
Specifications subject to change without notice.
– 46 –
180 Watts
310 Watts
620 Watts
125 Watts
225 Watts
450 Watts
Typically 40dB
>100dB (A-weighted)
20Hz-20,000Hz 0.5dB
10Hz–250kHz 3dB
>200
50V ms
<0.05%
20k Ohms
28V max. input
Variable from 300mV to 5V
Variable form 100mV to 960mV
60 Amp or two 30 Amp
AGU / Maxi Fuse
12dB or 24dB/octave Butterworth
80Hz (0.047mf)
Full Range
9-5/8"W x 14-9/32"L x 2-5/8"H
(24.4cm) x (36.27cm) x (6.6cm)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power 250.1Power 250.2

Table of Contents