T8635L MICROELECTRONIC COMMUNICATING PROGRAMMABLE THERMOSTAT
Table 6. Installer Setup Numbers and Default Settings and Options. (Continued)
Installer
Setup
Number
(Press
key to
change)
Description
37
Field calibration
adjustment.
43
Filter timer.
44
Backlight operates
continuously or with a
key press.
45
Outdoor temperature
sensor.
46
Enable humidity display. Global 0
51
Stage 1 heat cycle rate. Global 6
52
Stage 2 heat cycle rate.
55
Emergency heat cycle
rate.
57
Stage 1 cool cycle rate. Global 3
58
Stage 2 cool cycle rate.
ADV
Advance configuration
menu to review/modify
equipment ID and type.
a
This value is not installer adjustable. If any of these Installer Setup No. are changed: 4, 5, 8, 9, 51, 52, 55-ADV from
Table 6 and 62-63, 65-69, 71-73, 75-80 from Table 7, the settings are locked and Automatic Discovery cannot
occur. To unlock Discovery, advance to "dIS" and press the
covery, "wait" appears in the display for approximately 20 seconds and the thermostat is not functional.
b
3 cph when used with W8635B or W8835 configured for heat pump; 9 cph when used with the T8635 set for electric
heat.
IMPORTANT
Review the settings to confirm that they are correct for your application. Press Run Program key to exit
Installer Setup. The settings will be saved indefinitely in memory. Upon exiting Installer Setup, "wait"
appears in the display for approximately 20 seconds.
Set the time and day on the last thermostat configured after exiting Installer Setup. See Setting Current Day
and Time section.
69-1331—5
Default Setting
Scope
Display
Description
Local
0
No difference
between displayed
temperature and
actual room
temperature.
Global 0
Thermostat filter timer
is used.
Local
0
Backlight operates
with a key press.
Local
0
Outdoor temperature
sensor is not
configured.
Humidity display
disabled.
Cycle rate of
b
equipment (cph).
Global 9
Cycle rate of
equipment (cph).
Cycle rate of
equipment (cph).
ADV
No access to
off.
Advanced Installer
Setup No. 61-63,
65-69, 71-73, 75-79.
12
Other Options (Press
Display
-3, -2, -1,
1, 2, 3
1
1
1
1
1, 2, 3, 4,
5, 6, 7, 8,
9, 10, 11,
or 12
1, 2, 3, 4,
5, 6, 7, 8,
9, 10, 11,
or 12
0, 1, 2, 3,
4, 5, 6, 7,
8, 9, 10,
11, or 12
ADV on
key to manually initiate Discovery mode. During Dis-
or
key to change
Description
Display adjusts to the
chosen °F higher or
lower than room
temperature.
External filter timer is
used.
Backlight operates
continuously.
Outdoor temperature
sensor is configured.
Humidity display
enabled.
Cycle rate of equipment
(cph).
Cycle rate of equipment
(cph).
Cycle rate of equipment
(cph).
Access to Advanced
Installer Setup No. 61-63,
65-69, 71-73, 75-79.