DM2000
35.

Cannon Connector

(Time required: About 15 minutes)
35-1. Remove the rear panel. (See procedure 32.)
35-2. Remove the two (2) screws marked [110] from the
rear side. The cannon connector can then be
removed. (Fig.15)
The opposite cannon connector can be removed in
the same manner.
36.

DSUB Cable

(Time required: About 15 minutes)
36-1. Remove the rear panel. (See procedure 32.)
36-2. Remove the screw marked [150F]. The cable holder
can then be removed. (Fig.15)
36-3. Remove the DSUB cable with the bushing. (Fig.15)
The bushing is not part of the DSUB cable.
When you replace the DSUB cable, you should
remove the bushing from the cable, and attach
in the new cable.
Meter angle L
<Left side view>
<Front view>
<Bottom view>
<Rrar view>
[160G]:Bind Head Tapping Screw-B