Yamaha YHT-S300 Service Manual page 34

Subwoofer integrated receiver sr-300, speakers ns-br300/ns-p705/ns-b380
Hide thumbs Also See for YHT-S300:
Table of Contents

Advertisement

SR-300/NS-BR300/NS-P705/NS-B380
● Starting Self-diagnostic function in
the protection cancel mode
If the protection function works and causes hindrance to
trouble shoot, cancel the protection function as described
below, and it will be possible to enter the self-diagnostic
function mode.
With this unit in the stand-by mode, press the keys on the
remote control in the order as shown below.
The self-diagnostic function mode is activated with the
protection functions disabled.
Opening message / オープニング表示
N o
P R T
In this mode, the "SLEEP" segment of the FL display
of this unit flashes to indicate that the mode is self-
diagnostic function mode with the protection functions
disabled.
CAUTION!
Using this product with the protection function disabled
may cause further damage to itself. Use special care
when using this mode.
34
● プロテクション解除モードでの起動
プロテクションが動作することにより、故障箇所の診断
に支障をきたすような場合は、次の方法によりプロテク
ションを解除した状態でダイアグモードに入ることがで
きます。
スタンバイ状態で、リモコンキーを下記の順に押します。
プロテクション解除モードでダイアグが起動します。
Keys on the remote control / リモコンキー
Display / ディスプレイ表示
After a few seconds / 数秒後
このモードでは本機 FL の SLEEP セグメントが点滅し、
プロテクションを解除した状態でのダイアグモードであ
ることを知らせます。
注意!
プロテクションを解除した状態でのダイアグモードは、
危険な状態でもプロテクションが作動しないため、動作
させると、機器を破壊することがあります。このモード
を使用する場合は十分注意してください。
3
1
2
Main menu display / メインメニュー表示
1 - 1
V O L
0
"SLEEP" segment
SLEEP セグメント

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yht-s400Yht-s350Yht-s1400

Table of Contents