Unit Settings and data Reading

4.3 Reading Analog Input Data

4.3.1 Reading Analog Input Data
Basic Operation of Analog Input Processing
(1) Receiving analog input
The analog input unit receives analog input data from devices, such as laser analog sensors
and pressure sensors.
(2) Digital conversion processing
Analog input data received by the unit is converted into digital values in sequence
automatically in the unit. The converted digital value varies with the setting of the range.
(3) Storage of digital values
A user program is used to read converted digital values as data in the input relay area (WX).
The specified area number varies depending on the installation position of the unit.
(3)
Program to Acquire Converted Digital Values
Reading the values in digital conversion value storage areas WX10, WX12, WX14, and WX16
to any a reas of data registers ranging from DT100 to DT103.
R0
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
4-8
(2)
(1)
V or I
MV.SS
MV.SS
MV.SS
MV.SS
t
WX10
DT100
CH0 input
WX12
DT101
CH1 input
WX14
DT102
CH2 input
WX16
DT103
CH3 input
Transferring the digital
data in analog input
areas WX10, WX12,
WX14, and WX16 to
data registers ranging
from DT100 to DT103.

Advertisement

Table of Contents
loading

Table of Contents