Quick Links

ATEN Altusen
Online Registration
• http://eservice.aten.com
KH1508
/KH1516
Cat 5 High-Density KVM Switch
A
A
Technical Phone Support
Quick Start Guide
International:
• 886-2-8692-6959
China:
© Copyright 2014 ATEN
®
International Co., Ltd. www.aten.com
• 86-10-5255-0110
Altusen and the Altusen logo are trademarks of ATEN International Co., Ltd.
Japan:
All rights reserved. All other trademarks are the property of their respective owners.
• 81-3-5615-5811
Korea:
This product is RoHS compliant
PAPE-1214-Q30G
Printing Date: 10/2014
• 82-2-467-6789
North America:
• 1-888-999-ATEN Ext: 4988
United Kingdom:
• 44-8-4481-58923
All information, documentation, firmware, software utilities, and specifications contained in this package are subject to change without
prior notification by the manufacturer. Please visit our website http://www.aten.com/download/?cid=dds for the most up-to-date versions.
1
Package Contents
1 KH1508
or KH1516
Cat 5 High-Density KVM Switch
1 Mounting Kit
A
A
1 Firmware Upgrade Cable
1 Foot Pad Set (4 pcs.)
1 Power Cord
1 User Instructions
Important Notice
Considering environmental protection, ATEN does not provide a fully printed user manual for this product. If the
information contained in the Quick Start Guide is not enough for you to configure and operate your product, please visit
our website www.aten.com, and download the full user manual.
2
Requirements
Console
• A VGA, SVGA, or multisync monitor capable of the highest resolution that you will be using on any computer in
the installation
• A PS/2 or USB mouse
• A PS/2 or USB keyboard
Computers
The following equipment must be installed on the computers that connect to the KH1508
ports:
• A VGA, SVGA or multisync port
• A Type A USB port and USB host controller (for USB KVM adapter cable connection, see following section)
- or -
• 6-pin Mini-DIN keyboard and mouse ports (for PS/2 KVM adapter cable connection, see following section)
KVM Adapter Cables
• Cat 5e/6 cable is required to connect the KH1508
/ KH1516
to one of the KVM adapter cables.
A
A
• The following KVM adapter cables are required for use with the KH1508
A
Function
Module
Connect to devices with PS/2 ports
KA7920 / KA7520 / KA7120
Connect to devices with USB ports
KA7970 / KA7570 / KA7170
KA7166 /KA7168 / KA7169
Connect to Sun Legacy systems (with 13W3 port)
KA7130
Connect to Sun USB systems
KA7170
Connect to serial based devices
KA9140
3
1. Port Selection Pushbuttons
2. Port LEDs
3. Reset Switch
4. Firmware Upgrade Recovery Switch
4
1. Power Socket
2. Power Switch
3. Daisy Chain Ports
4. Grounding Terminal
Note: The front and rear panel views are similar for the KH1508
KH1508
5-1
Rack Mounting
The KH1508
A
or the back of the unit so that it can attach to the front or the back of the rack. To rack mount the unit:
1. Remove the screws at the front or the rear, as shown in the diagram below.
or KH1516
KVM
A
A
2. Screw the mounting brackets into the sides of the unit at the front or the rear, as shown in the diagram below.
/ KH1516
:
A
3. Slide the unit into the front or rear of the rack and secure it to the rack.
Hardware Review (Front View)
1&2
3
4
5
6
7
5. Firmware Upgrade Port
6. Power LED
7. Station ID LED
Hardware Review (Rear View)
1
2
3
4
5
6
5. Console Ports
6. KVM Port Section
, the difference being that the
A
has only one row of LED lights (front) and one row of CPU ports (rear)
A
Hardware Installation
/ KH1516
can be mounted in a 19" (1U) rack. The mounting brackets can screw into either the front
A
Phillips head hex
M3 x 6
Phillips head hex
M3 x 6
Phillips head hex
M3 x 8
5-2
Hardware Installation
Single Station Installation
1. Ground the KH1508
/ KH1516
by connecting one end of the grounding wire to the grounding terminal, and
A
A
the other end of the wire to a suitable grounded object.
(KH1516
)
A
Note: Do not omit this step. Proper grounding helps to prevent damage to the unit from surges or static
electricity.
2. Plug the console keyboard, monitor, and mouse into the unit's console ports. The ports are color coded and
marked with icons for easy identification.
Note: You can use any combination of keyboard and mouse connections. For example, you can use a PS/2
keyboard with a USB mouse.
3. Use Cat 5e/6 cable to connect any available KVM port to a KVM adapter cable that is appropriate for the
computer you are installing.
Note: To support a resolution of 1280x1024, the recommended maximum distance between the unit and the
KVM adapter cable is 50 meters.
4. Connect the KVM adapter cable to the computer. Plug the connectors on the KVM adapter cable into the
appropriate ports of the computer you are installing.
5. Plug the female end of the power cord into the KH1508
AC power source.
After the KH1508
/ KH1516
is cabled up, you can turn on the power. After it is powered up, you can turn on the
A
A
servers.
(KH1516
)
A
5
1
2
2
/ KH1516
's power socket; plug the male end into an
A
A
4
3
3

Advertisement

loading

Summary of Contents for ATEN Altusen KH1508a

  • Page 1 Note: The front and rear panel views are similar for the KH1508 , the difference being that the Considering environmental protection, ATEN does not provide a fully printed user manual for this product. If the KH1508 has only one row of LED lights (front) and one row of CPU ports (rear) information contained in the Quick Start Guide is not enough for you to configure and operate your product, please visit our website www.aten.com, and download the full user manual.
  • Page 2 Specification Operation Hotkey Summary Table Port Selection KH1508 / KH1516 installations provide three methods to obtain instant access to any computer on your Invokes Auto Scan mode. Function KH1508 KH1516 installation: Manual, OSD (on-screen display), and Hotkey. When Auto Scan mode is in effect, [P] or left-click Direct [A] [Enter] pauses auto-scanning.

This manual is also suitable for:

Altusen kh1516a