IBM System x3750 M4 Installation And Service Manual page 749

Types 8722 and 8733
Hide thumbs Also See for System x3750 M4:
Table of Contents

Advertisement

81010b01-2d01ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
deasserted.
Explanation: IMM has detected that the PCH temperature has returned to a normal range.
May also be shown as 81010b012d01ffff or 0x81010b012d01ffff
Severity: Info
Alert Category: Critical - Temperature
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0499
SNMP Trap ID: 0
Automatically notify Support: No
User response: Information only; no action is required.
81030006-2101ffff
Sensor [SensorElementName] has asserted.
Explanation: Signature verification of one of the Firmware Volumes or Capsules in UEFI BIOS failed.
May also be shown as 810300062101ffff or 0x810300062101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0508
SNMP Trap ID:
Automatically notify Support: No
User response: Automatic BIOS Recovery (ABR) should cause system to come up from UEFI image in backup bank.
Reflash UEFI image in the primary bank. If error does not persist no additional recovery action is required.
81030108-0a01ffff
Sensor [SensorElementName] has deasserted.
Explanation: The power supply load has returned to a normal state.
May also be shown as 810301080a01ffff or 0x810301080a01ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
81010b01-2d01ffff • 81030108-0a01ffff