Parameter group
I/O parameters
Status monitoring parameters
6.2

Parameter list

Editable parameters

The values of the parameters marked with an asterisk (*) may be changed after commissioning. Make sure you back up the
parameters first as required if you desire to replace the motor. The default values of the parameters marked with two
asterisks (**) are motor dependent. They may have different default values when different motors are connected.
Par. No.
Name
p0748
CU invert digital outputs
Description: Inverts the signals at the digital outputs.
Bit 0 to bit 5: invert signal for DO 1 to DO 6.
Bit = 0: not inverted
Bit = 1: inverted
p0795
Digital inputs simulation
mode
Description: Sets the simulation mode for digital inputs.
Bit 0 to bit 9: set the simulation mode for DI 1 to DI 10
Bit = 0: terminal eval
Bit = 1: simulation
Note: If a digital input is used as signal source for the function "STO" then it is not permissible to select the
simulation mode and this is rejected.
This parameter is not saved when data is backed up.
p0796
Digital inputs simulation
mode setpoint
Description: Sets the setpoint for the input signals in the digital input simulation mode.
Bit 0 to bit 9: set the setpoint for DI 1 to DI 10
Bit = 0: low
Bit = 1: high
Note: This parameter is not saved when data is backed up.
p1001
Fixed speed setpoint 1
Description: Sets a value for the fixed speed / velocity setpoint 1.
p1002
Fixed speed setpoint 2
Description: Sets a value for the fixed speed / velocity setpoint 2.
p1003
Fixed speed setpoint 3
Description: Sets a value for the fixed speed / velocity setpoint 3.
p1004
Fixed speed setpoint 4
Description: Sets a value for the fixed speed / velocity setpoint 4.
p1005
Fixed speed setpoint 5
Description: Sets a value for the fixed speed / velocity setpoint 5.
p1006
Fixed speed setpoint 6
Description: Sets a value for the fixed speed / velocity setpoint 6.
Getting Started
A5E36037886-003, 04/2017
Available parameters
p293xx
All read-only parameters
Min
Max
0
63
1
429496729
5
1
429496729
5
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 00.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
Parameter group display on
the BOP
Factory
Unit
Data
Setting
type
0
-
U32
0
-
U32
0
-
U32
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U