Coleman TCGD18 Technical Manual

Coleman TCGD18 Technical Manual

Split-system air conditioners 13 seer – r-410a – 1 phase

Advertisement

TECHNICAL GUIDE
SPLIT-SYSTEM
AIR CONDITIONERS
13 SEER – R-410A – 1 PHASE
MODELS:
TCGD18 THRU 60
(1.5 THRU 5 NOMINAL TONS)
Due to continuous product improvement, specifications are
subject to change without notice.
Visit us on the web at www.york.com
Additional rating information can be found at
www.ahridirectory.org
WARRANTY
Standard 5-year limited parts warranty.
Standard 5-year limited compressor warranty.
Extended 10-year limited parts warranty when product is
registered online within 90 days of purchase for replace-
ment or closing for new home construction.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
The 13 SEER Series unit is the outdoor part of a versatile cli-
mate system. It is designed with a matching indoor coil compo-
nent from Johnson Controls Unitary Products. Available for
typical applications this climate system is supported with acces-
sories and documents to serve specific functions.
FEATURES
• Quality Condenser Coils - The coil is constructed of alumi-
num microchannel tubing and enhanced aluminum fins for
increased efficiency and corrosion protection.
• Protected Compressor - The compressor is internally pro-
tected against high pressure, temperature, and externally by
a factory installed high pressure switch. This is accomplished
by the simultaneous operation of high pressure relief valve
and a temperature sensor which protects the compressor if
undesirable operating conditions occur. A liquid line filter-
drier further protects the compressor.
• Durable Finish - The cabinet is made of pre-painted steel.
The pre-treated galvanized steel provides a better paint to
steel bond, which resists corrosion and rust creep. Special
primer formulas and matted-textured finish insure less fading
when exposed to sunlight.
• Lower Installed Cost - Installation time and costs are
reduced by easy power and control wiring connections.
Available in sweat connect models only. The unit contains
enough refrigerant for matching indoor coils and 15 feet of
interconnecting piping. The small base dimension means
less space is required on the ground or roof.
• Top Discharge - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
• Low Operating Sound Level - The upward air flow carries
the normal operating noise away from the living area. The
rigid top panel effectively isolates any motor sound. Isolator
mounted compressor and the rippled fins of the condenser
coil muffle the normal fan motor and compressor operating
sounds.
• Low Maintenance - Long life permanently lubricated motor-
bearings need no annual servicing.
• Easy Service Access - Fully exposed refrigerant connec-
tions, and a single panel covering the electrical controls
make for easy servicing of the unit.
• Secured Service Valves - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections
for ease of evacuating and charging.
• U.L. and C.U.L. listed - approved for outdoor application.
• Agency Listed - U.L. and C.U.L. listed - approved for out-
door application. The unit is certified in accordance with the
Unitary Small Equipment certification program, which is
based on ARI Standard 210/240.
359317-CTG-G-0509

Advertisement

Table of Contents
loading

Summary of Contents for Coleman TCGD18

  • Page 1 MODELS: and a temperature sensor which protects the compressor if TCGD18 THRU 60 undesirable operating conditions occur. A liquid line filter- (1.5 THRU 5 NOMINAL TONS) drier further protects the compressor.
  • Page 2: Physical And Electrical Data

    359317-CTG-G-0509 Physical and Electrical Data TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 MODEL S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1 Unit Supply Voltage 208-230V, 1 60Hz 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 12.4 14.7 17.9 21.5 21.1 34.3...
  • Page 3: System Charge For Various Matched Systems

    359317-CTG-G-0509 System Charge for Various Matched Systems TCGD18 TCGD24 TCGD30 TCGD36 TCGD42 TCGD48 TCGD60 Outdoor Unit S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1(H) S41S1 0.048/4F1 0.055/4F1 0.061/4F1 0.065/4G1 0.075/4G1 0.073/4H1 0.087/4J1 Required Orifice or TXV Factory Charge, lbs-oz 3 - 3...
  • Page 4 359317-CTG-G-0509 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH MA TCGD18S41S1(H) MA08B FC/MC18B 17.5 12.9 13.00 11.00 MA08B FC/MC36B 24.0 16.7 13.00 11.00 TCGD24S41S1(H) MA08B FC/MC35B...
  • Page 5 359317-CTG-G-0509 COOLING CAPACITY - With Air Handler Coils (Continued) AIR HANDLER COOLING UNIT COIL NET MBH RATED MODEL MODEL MODEL SEER TOTAL SENS. 13 SEER AC WITH AHP / SHP / AHX / F*FP AHP18 – 17.5 12.9 13.00 11.00 AHX18 18.0 13.8...
  • Page 6 359317-CTG-G-0509 COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils FURNACE** COOLING COIL NET MBH UNIT MODEL CFM RANGE RATED MODEL SEER (Min.-max.) TOTAL SENS. 450 - 750 14,17 FC/MC/PC18 17.5 12.9 13.00 11.00 TCGD18S41S1(H) 450 - 750 HC18 17.5 12.9 13.00...
  • Page 7 359317-CTG-G-0509 COOLING CAPACITY - With High Efficiency Motor Furnaces COOLING FURNACE COIL MODELS Net MBH RATED MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*A12 FC/MC/PC18A 17.7 12.9 14.50 12.50 T*(8,L)X*B12 FC/MC/PC18B 18.0 13.4 14.50 12.50 T*9X*B12 FC/MC/PC18B 18.0...
  • Page 8 359317-CTG-G-0509 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING FURNACE COIL MODELS Net MBH RATED MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*9X*C20 FC/MC/PC43C 28.2 19.3 14.00 12.00 C*(8,L)C*A12 FC/MC/PC32A 1045 29.2 21.8 13.20 11.00 C*(8,L)C*B12...
  • Page 9 359317-CTG-G-0509 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING FURNACE COIL MODELS Net MBH RATED MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES C*(8,L)C*C20 HC42 1190 35.6 25.6 14.00 12.00 (C*9C/T*9V)*C16 HC42 1240 35.4 25.2 13.50 11.50...
  • Page 10 359317-CTG-G-0509 COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued) COOLING FURNACE COIL MODELS Net MBH RATED MODEL MODEL SEER TOTAL SENS. 13 SEER HP WITH VARIABLE SPEED FURNACES T*(8,L)X*C16 FC/MC/PC48C 1600 48.0 34.4 13.30 11.00 T*(8,L)X*C20 FC/MC/PC48C 1660 48.0 34.4 13.20 11.00...
  • Page 11: Sound Power Ratings

    359317-CTG-G-0509 ACCESSORIES Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and Refer to Price Manual for specific model numbers. installation, refer to the UPGNET “Low Voltage Wiring Diagram” Off Cycle Timer Delay - Provides a 5-minute off cycle to pre- document to select and apply controls.
  • Page 12: Cooling Performance Data

    359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD18S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC18 IDCFM CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 15.7 17.8 17.7 19.3 19.9 16.9 18.4 18.0 19.5 20.2 18.0 18.9 18.4 19.6 20.4 S.C.
  • Page 13 359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD24S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC36 IDCFM 1000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 22.0 27.4 27.3 29.1 30.3 24.3 28.8 28.6 30.4 31.7 26.6 30.1 29.8 31.8 33.2 S.C.
  • Page 14 359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD30S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC35 IDCFM 1000 1200 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 28.4 31.4 30.8 33.1 34.4 29.8 31.8 31.4 33.4 34.5 31.2 32.3 32.1 33.7 34.7...
  • Page 15 359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD36S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1000 1200 1400 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 34.7 36.1 35.2 37.4 37.3 33.8 35.5 34.8 37.0 37.5 32.9 34.9 34.4 36.6...
  • Page 16 359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD42S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC43 IDCFM 1200 1400 1600 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 44.4 45.5 43.6 47.0 48.5 45.9 46.5 45.0 48.5 49.8 47.5 47.5 46.5 50.1...
  • Page 17 359317-CTG-G-0509 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD48S41S1(H) INDOOR COIL MODEL NO. FC/MC/PC48 IDCFM 1400 1600 1800 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 49.7 51.4 50.6 55.8 54.6 52.0 53.1 51.9 56.4 55.4 54.4 54.7 53.2 56.9...
  • Page 18 COOLING PERFORMANCE DATA AIR CONDITIONER MODEL NO. TCGD60S41S1 INDOOR COIL MODEL NO. FC/MC/PC60 IDCFM 1600 1800 2000 CONDENSING ENTERING AIR ID DB (°F) TEMPERATURE ID WB (°F) T.C. 55.8 63.8 62.1 65.2 71.9 60.3 65.7 62.8 66.7 69.8 64.8 67.5 63.5 68.2 67.8...

This manual is also suitable for:

Thru 60Tcgd24Tcgd30Tcgd36Tcgd42Tcgd48 ... Show all

Table of Contents