Unit Dimensions −− Inches (mm)
DISCHARGE AIR
39−1/2
(1003)
SIDE VIEW
UNIT SUPPORT
FEET
16−7/8
(429)
8−3/4
(222)
3−1/8
30−3/4
(79)
(781)
BASE WITH ELONGATED LEGS
WARNING
This product and/or the indoor unit it is matched
with may contain fiberglass wool.
Disturbing
the
insulation
maintenance, or repair will expose you to fiberglass
wool dust. Breathing this may cause lung cancer.
(Fiberglass wool is known to the State of California
to cause cancer.)
Fiberglass wool may also cause respiratory, skin,
and eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact
your supervisor.
Lennox Industries Inc.
P.O. Box 799900
Dallas, TX 75379−9900
505328M 06/09
ELECTRICAL INLETS
VAPOR LINE
INLET
LIQUID LINE
INLET
DEFROST CONTROL
OPERATION MONITOR
VAPOR VALVE AND
26−7/8
GAUGE PORT
(683)
DISCHARGE LINE
REVERSING VALVE
3−3/4 (95)
FILTER DRIER
4−5/8
(117)
during
installation,
Page 2
37 (940)
[−024 thru −042]
47 (1194)
[−048 and −060]
4−7/16
(113)
18−1/2
(470)
8 (203)
1 (25)
CONTACTOR
SYSTEM
VAPOR LINE
XP15 Parts Arrangement
General Information
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
who have jurisdiction before installation.
When servicing or repairing HVAC components, ensure
caps and fasteners are appropriately tightened. Table 1
lists torque values for typical service and repair items.
Table 1. Torque Requirements
Part
Service valve cap
Sheet metal screws
Machine screws #10
Compressor bolts
Gauge port seal cap
35−1/2
(902)
ACCESS VIEW
OUTDOOR FAN
RUN CAPACITOR
COMPRESSOR
COMPRESSOR
SOUND DOME
COMPRESSOR
TERMINAL PLUG
LOW PRESSURE
SWITCH
HIGH PRESSURE
SWITCH
Recommended Torque
8 ft.− lb.
11 NM
16 in.− lb.
2 NM
28 in.− lb.
3 NM
90 in.− lb.
10 NM
8 ft.− lb.
11 NM