User Guide
C on trol M od u l e
TH131
Pilot wire
Heating command
indicator
Indicator
(European
model only
230 V
ON/OFF switch
Temperature
selection dial
TH133
Install the Control Module
Align the bracket tabs on the control module with the
holes located on the power base and secure using the
screw.
Control Module
Power Base
NOTE:
Keep the thermostat's air vents clean and free
from obstructions.
NOTE:
The screw cannot be removed completely.
Thank you for choosing an Aube product.
The TH131 and TH133 non programmable thermostats
are equipped with a microprocessor and proportional
integral adaptive (PIA) temperature control technology.
They can be installed on a 230 V power base (European
model) or a 24 V low voltage base and combined with an
electromechanical or TRIAC relay.
The TH131 can use all six pilot wire commands when
installed on a 230 V power base (see section 4).
Configure the Switches
Position the switch according to your application:
Model
Switch
Temperature Control
AMBIENT
A
UP (A/AF)
(no floor sensor)
AMBIENT WITH FLOOR LIMIT
AF
UP (A/AF)
(requires a floor sensor)
FLOOR
F
DOWN (F)
(requires a floor sensor)
(ambient sensor is deactivated)
Pilot Wire Commands
EUROPEAN MODEL ONLY (230 V BASE)
The TH131 accepts the six pilot wire commands:
1
SIGNAL
COMMAND
MODE
Heating as per
1
No signal
defined setpoint
Current setpoint
2
minus 3,5°C
3
Setpoint at 7°C
4
Stop heating
Current setpoint
5
minus 1°C
Current setpoint
6
minus 2°C
1.
1) Comfort 2) Reduced setpoint 3) Above freezing (min)
4) Stop heating 5) 1°C setback 6) 2°C setback
230 V LINE VOLTAGE BASE
ALWAYS 15 minutes
24 V LOW VOLTAGE BASE
• 15 MIN
Use
with
a
TRIAC
or
electromechanical relay.
Recommended
for
mechanical
actuated system (water heating
using a solenoid valve, etc.) or a
fan-forced heater.
• 15 SEC
Use only for installations with a solid state relay
(SSR). Recommended
for
electric
(baseboards, convectors, etc.).
The thermostat also features an On/Off switch making it
possible to turn off the thermostat when it is not required
(e.g. summer).

Technical Specifications

Models: TH131 and TH133 A / AF / F
Setting
Range: 45°F, 59°F to 95°F (7°C, 15°C to 35°C)
MIN: above-freezing temperature 45°F (7°C)
MAX: maximum temperature 95°F (35°C)
Potentiometers:
MIN: 41°F to 77°F (5°C to 25°C)
MAX: 59°F to 95°F (15°C to 35°C)
Storage: -4°F to 120°F (-20°C to 50°C)
Software: Class A
Controller: Electronic
Temperature
Control: Proportional integral adaptive,
15-minute or 15-second heating cycles
Accuracy: ± 0.36°F (0.2°C)
Size
(H/W/D):
TH131: 3.1 x 3.1 x 0.64 in (78.9 x 78.9 x 16.3 mm)
TH133: 3.1 x 3.1 x 0.71 in (78.9 x 78.9 x 18 mm)
Min/Max Temperature (TH1 31 only)
Use this feature to establish a temperature range by
setting minimum and maximum setpoints. Depending on
the model, you can establish the temperature range for:
the ambient air (A)
the floor (AF and F)
Use a flat tip screwdriver to
rotate the potentiometers
until the notch points to the
desired temperature.
When the temperature is
heating
set outside the temperature
range, it will revert to the
nearest setpoint.
Example: MIN is 59°F and MAX is 77°F.
Using the front dial, you set the temperature at 50°F,
the TH131 will revert to the minimum set value 59°F.
Using the front dial, you set the temperature at 86°F,
the TH131 will revert to the maximum set value 77°F.
Warranty and Service
AUBE TECHNOLOGIES INC. TWO (2) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a two-year
period following the initial date of purchase. During this period, AUBE
Technologies Inc. will repair or replace, at our option and without charge,
any defective product which has been used under normal conditions.
The warranty does not cover delivery costs and does not apply to products
poorly installed or randomly damaged following installation. This warranty
cancels and replaces any other manufacturer's express or implied
warranty as well as any other company commitment.
AUBE Technologies Inc. cannot be held liable for related or random
damages following the installation of this product. The defective product as
well as the purchase invoice must be returned to the place of purchase or
mailed, prepaid and insured, to the nearest address.
If you have any questions concerning the TH131 or TH133 thermostat, call
our technical support team at:
705 Montrichard
10 rue Ampère
Saint-Jean-sur-Richelieu
95500 Gonesse
Quebec, Canada J2X 5K8
France
Tel.: (450) 358-4600
33 (0) 1 34 07 99 00
Toll Free: 1-800-831-AUBE
Fax: (450) 358-4650
33 (0) 1 34 07 99 19
service@aubetech.com
advaube@comintes.com
13/01/2004
400-131-002-B

Advertisement

loading

Summary of Contents for Aube Technologies TH131AF

  • Page 1: Technical Specifications

    Potentiometers: warranty as well as any other company commitment. defined setpoint AUBE Technologies Inc. cannot be held liable for related or random MIN: 41°F to 77°F (5°C to 25°C) damages following the installation of this product. The defective product as...
  • Page 2: Installation And Wiring

    PB130-230 power base, contact our technical support team at: year period following the initial date of purchase. During this period, AUBE Technologies Inc. will repair or replace, at our option and without charge, any defective product which has been used under normal conditions.

This manual is also suitable for:

Th131aTh131fTh133aTh133afTh133f