Adjusting The Thermostat - Broan 349BR Manual

Roof-mount powered attic ventilator
Hide thumbs Also See for 349BR:
Table of Contents

Advertisement

Available languages

Available languages

12. Carefully lift shingles and nail flashing securely to the
roof using galvanized roofing nails.
13. Using a good grade of roofing cement material, seal
all of the shingles and heads of nails.
DO NOT seal the bottom edge of the flashing.
WIRING
IMPORTANT: Do not mount outlet box near heat source.
1. Mount the outlet box to a nearby rafter so that the outlet
box is higher than the fan motor.
BLACK
FROM MOTOR
FROM
FAN MOTOR
GROUND
CAUTION: Make sure fan and switches are properly
grounded and all wiring complies with local electrical
code requirements.
2. Remove the thermostat wiring box cover plate. Bring
120 VAC, 14-gauge-with-ground house power cable at
least 6" into the thermostat wiring box. Fasten cable to
box with appropriate connector.
3. An on/off switch can be installed in a convenient location
in the living area of the house so that the fan can be
turned off when not needed.

ADJUSTING THE THERMOSTAT

FAN ON TEMPERATURE
80
o
70
o
60
o
50
The fan thermostat is preset to 110
automatically start when the ambient temperature reaches
the set temperature and stop when the temperature
drops 10-degrees below the set temperature. The start
temperature can be adjusted from 60
MODEL 349BR
Page 4
BLACK
FROM HOUSE
CABLE
HOUSE
CABLE
WHITE FROM
MOTOR AND
HOUSE CABLE
o
o
90
o
100
o
110
o
120
F. The fan will
0
F to 120
F.
0
0

Advertisement

Table of Contents
loading

Table of Contents