Download Print this page
Honeywell L641A Installation Instructions

Honeywell L641A Installation Instructions

Cylinder thermostat

Advertisement

Quick Links

L641A - Cylinder Thermostat

Installation Instructions

The L641 is a water temperature thermostat designed for surface mounting on domestic hot
water cylinders. It is supplied complete with mounting strap for rapid and easy installation,
so draining of the system or tapping the cylinder is not necessary. The desired temperature
control point is set by the clearly scaled temperature selector on the front cover.
50
60
70
40
80°C
min
L641A1039
1
Mounting Position
The cylinder thermostat
should be mounted
to
of the way from the bottom
of the cylinder.
to
Height
3
Cover Removal
Caution: Isolate
power supply and
make safe before
wiring the unit to
prevent electric
shock and equipment
damage. Installation
should be carried
out by a competent
person.
Cover installation is the reverse of above
5
Wiring Diagram
Use connections C and 1 when
system operation is required on
temperature fall
* Terminal 2 used on
Y-Plan systems
~
230V
50..60Hz
3 AMPS
Timer/Programmer
Features
50
60
• Snap action SPDT Micro
70
40
Switch™.
80°C
• Wiring terminals are easily
min
accessible.
• Tamperproof temperature
setting.
L641A1039
• Optional manual setting
knob supplied
L641
*
C
1
2
Heating Load
Specification
Switch Action: SPDT, Type 1 CL.
Switch Rating: 230V~ 4(2)A 50...60Hz
Temperature Setting Range: 40...80°C
Differential: Approximately 10°C non-adjustable
Ambient Temperature Range: 0...55°C
Cylinder Surface Temperature Range: 0...95°C
2
Pre-insulated cylinder
preparation
Remove a section of
insulation as specified.
Clean cylinder surface
to ensure good surface
contact.
4
Wiring to terminals
All wiring must be in accordance with I.E.E. regulations.
Use heat resisting flexible cable rated at 85°C.
A switch, having contact separation of at least 3mm in all
poles, must be incorporated in the fixed wiring as a means of
disconnecting the supply.
The thermostat is a class II (double insulated device) requiring no
earth connection.
The heating system must be appropriately fused with a fuse rating
of no higher than 3 amps.
For use in normal domestic environments.
EMC compliance considerations
Keep AC mains supply/load cables separate from signal wiring.
Refer to Code of Practice EN61000-5-1 and -2 for guidance.
80mm
45mm

Advertisement

loading

Summary of Contents for Honeywell L641A

  • Page 1: Installation Instructions

    L641A - Cylinder Thermostat Installation Instructions The L641 is a water temperature thermostat designed for surface mounting on domestic hot water cylinders. It is supplied complete with mounting strap for rapid and easy installation, so draining of the system or tapping the cylinder is not necessary. The desired temperature control point is set by the clearly scaled temperature selector on the front cover.
  • Page 2 This product has been designed for applications as described within this document. For use outside of the scope as described herein, refer to Honeywell for guidance. Honeywell cannot be held responsible for misapplication or the product(s) described within this document.