MAINTENANCE (CLEANING) CONTINUED
4. Using a cloth dampened with kitchen detergent, remove
any dirt from fan body. Wipe dry with clean cloth. (Fig.15)
5. Reinstall grille.
WARNING
Make sure the temperature of LED unit has cooled
down before maintenance
(cleaning) or replacement of lamp.

PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan to
minimize building heat loss and gain. (Fig.16)
Loose fill or batt insulation can be placed
directly over the fan housing in the attic.
Our fans does not create excessive heat that
is a common problem with recessed light
fixtures or some competitor's fan/light
combination. Our efficient, cool-running
motors do not create enough ambient heat
to be subjected to these limitations.
The ducting from this fan to the outside of
the building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not achieve their rated air flow.

SPECIFICATIONS

Air
Model No.
direction
FV-0511VQL1
Exhaust
FV-1115VQL1
Exhaust
FV-0511VQCL1
Exhaust
HVI Certified performance based on HVI Procedures 915, 916, and 920.
Duct
Voltage
Frequency
diameter
(V)
(Hz)
(inches)
120
60
4 or 6
120
60
6
120
60
4 or 6
Gloves
4 inches or 6 inches roof jack, wall cap,
or soffit vent with backdraft damper
Mechanically connect duct to termination
and seal with mastic or approved foil
faced tape
2-3 ft straight run before elbow
ln attic installation,
caulk box to drywall
Short piece of flexible duct helps
alignment and absorbs sound.
Clamps plus mastic or approved
foil faced tape at all flex joints
Air volume
Noise
at 0.1"WG
(sones)
(CFM)
50
<0.3
80
<0.3
110
0.4
110
<0.3
130
<0.3
150
0.5
50
<0.3
80
<0.3
110
0.4
Ceiling
Foil tape tightly covers all metal
duct joints (glue PVC joints)
Speed
Power
(rpm)
(W)
768
4.0
867
6.1
1016
11.0
679
7.8
722
10.4
740
13.1
768
4.0
867
6.1
1016
11.0
English
Fig.15
lnsulation
Fig.16
Weight
Ib.(kg)
9.9(4.5)
10.1(4.6)
10.1(4.6)
11