Plc Status Registers - Mitsubishi FX1S series Hardware Manual

Hide thumbs Also See for FX1S series:
Table of Contents

Advertisement

FX1S Series Programmable Controllers
7.6

PLC Status Registers

Table 7.4: PLC Status Registers
D8000
(default 200msec)
D8001
D8002
D8003
D8004
Watchdog timer
PLC version
22100 = FX
Version 1.00
1S
22 = FX
, 100 = Version 1.00
1S
Memory capacity
0002=2K steps
Memory type
02H=EEPROM protect switch OFF
0AH=EEPROM protect switch ON
10H=MPU memory
Error flag number
8060=M8060, (8060-8068)
Diagnostics 7
1
2
3
4
5
6
7
7-5