3.
Name and function of switches
Installation and
operation manual
a
3P419248-1-KA
The English text is the original instruction. Other languages are
translations of the original instructions.
9
Refer
to
http://www.daikineurope.com/support-and-manuals/
4
product-information/
for more detailed user reference guides.
Installation: see
page
2.
5
1
OPERATION
3
1.
General safety precautions
2
Also see operation manual attached to the outdoor and
indoor unit.
1 OPERATION MODE SELECTOR BUTTON
Please read these
"1. General safety precautions"
carefully before
installing air conditioning equipment and be sure to install it
To select the operation mode of your preference.
correctly.
2 FAN SPEED/AIRFLOW DIRECTION SETTING BUTTON
Failure to follow these instructions properly may result in property
To enter the fan speed/airflow direction setting screen.
damage or personal injury, which may be serious depending on the
circumstances.
3 MENU/ENTER BUTTON
WARNING
To enter the main menu or the selected setting item.
Do NOT play with the unit or its remote controller.
4 UP/DOWN BUTTON
Accidental operation by a child may result in impairment of
To raise/lower the set temperature, to highlight the next item on the
bodily functions and harm health.
upper/lower side or to change the selected item.
WARNING
5 RIGHT/LEFT BUTTON
Never disassemble the remote controller. Touching the
To highlight the next item on the right/left-hand side.
interior parts may result in electric shocks or fire. Consult
6 ON/OFF BUTTON
your Daikin dealer or authorized contactor for internal
To start or stop the system.
inspections and adjustments.
INFORMATION
WARNING
This is the only button that works when the backlight is not
To avoid electric shocks, do not operate with wet hands.
lit.
7 OPERATION LAMP
WARNING
Lights up during operation or blinks if a malfunction occurs.
 Do NOT modify or repair the remote controller. This
may result in electric shocks or fire. Consult your
8 CANCEL BUTTON
Daikin dealer.
To return to the previous screen.
 Do NOT relocate or reinstall the remote controller by
yourself. Improper installation may result in electric
9 LCD (with backlight)
shocks or fire. Consult your Daikin dealer.
When pushing any operation button, the backlight will be lit for
 Do NOT use flammable materials (e.g. hairspray or
approximately 30 seconds. When 1 indoor unit is controlled by 2
insecticide) near the product. Do not clean the
remote controllers, the backlight of the remote controller operated
product with organic solvents such as paint thinner.
earlier than the other one will be lit.
The use of organic solvents may cause crack damage
to the product, electric shocks, or fire.
4.
Name and function of icons
2.
Features and functions
To change between the standard display and the detailed display
refer to
"17.4 To select the display
The BRC1E53 is a state of the art remote controller that offers full
control over your installation.
Standard display
1 BASIC REMOTE CONTROLLER
With icons
The basic remote controller functions are:
 ON/OFF,
10
 operation mode change-over,
9
 temperature adjustment,
 air volume adjustment,
1
 airflow direction adjustment.
2
2 CLOCK FUNCTION
6
The clock functions are:
5
 12/24 hours real time clock,
 automatic daylight saving time.
Detailed display
3 SCHEDULE FUNCTION
The schedule timer functions are:
With icons
 a maximum of 5 actions can be programmed for each day of
15
the week,
16
 3 independent schedules can be programmed,
 schedule can be enabled/disabled at any time,
12
 linked to a cool temperature and/or heat temperature or an
OFF operation (with or without a setback temperature),
 "last command" overrules previous command until next
scheduled command.
4 SETBACK
1 OPERATION MODE
The setback function maintains the room temperature in a specific
range when the occupants are out for a longer period and the
airconditioning is switched OFF.
cool
5 PROHIBIT BUTTON/FUNCTION
Buttons, functions and/or modes can be locked to limit the user
action.
Fan
6 DETAILED DISPLAY POSSIBILITY
Additionally possible to display the outdoor temperature or room
temperature.
7 Duty rotation
2 FAN SPEED
Indicates the fan speed that is set for the air conditioner. If the air
Auto
backup
unit
and
auto
rotation
to
maximize
your
airconditioners' life.
conditioner does not have fan speed control function, the fan speed
will not be displayed.
8 Demand control
3 SET/SETBACK TEMPERATURE DISPLAY
Make up an energy reduction schedule.
When the unit is turned on, Set to indicates the temperatures that
9 Quiet mode
are set for the air conditioner.
Schedule a quiet mode for your outdoor unit(s).
When the unit is turned off, Setback indicates the temperatures that
are set for the setback function.
10 INTERLOCK WITH 2 EXTERNAL SIGNALS
(Only available when the BRP7A51 Digital Input Adapter is
4 DEFROST/HOT START
connected)
Indicates that the defrost/hot start mode is active.
 Connect up to two switch contacts (contact B1 and B2).
 Typical application: hotel interlock with field supplied window
contact B1 and key card B2.
Installation and operation manual
1
5 MESSAGE
Messages can be displayed.
6 VENTILATION/CLEANING
 Ventilation mode icons
ventilation mode (HRV only) (AUTOMATIC, ENERGY RECLAIM VENT.,
BYPASS).
 Air Cleaning unit icon
(option) is operational.
7
DISPLAY
Indicates that the key lock is set or the menu button is prohibited.
7
8
DISPLAY
6
Indicates that schedule timer or OFF timer is enabled.
DISPLAY
8
Indicates that the clock needs to be set. The schedule timer
function will not work until the clock is set.
9 EXTERNAL CONTROL ICON
Indicates that another controller with higher priority is controlling or
disabling your remote controller.
10 CHANGEOVER UNDER CENTRALISED CONTROL ICON
Indicates that the changeover of the installation is under
centralised control assigned to another indoor unit or optional cool/
heat selector connected to the outdoor unit (= master remote
controller).
11 SETBACK ICON
Flashes when the unit is turned on under the setback control.
12 AIRFLOW DIRECTION
Is displayed when the airflow direction and swing are set.
13 CLOCK (12/24 Hours real time clock)
Is displayed when the clock is set. If the clock is not set, - : - is
displayed.
14 DETAILED SELECTION
Is displayed when the detailed display items are selected.
15 ROTATION
Indicates one unit is set as back-up and rotation mode is enabled.
16 QUIET MODE
Indicates the HVAC system runs in quiet mode or under demand
control.
5.
Description of the operation modes
1 FAN ONLY OPERATION
mode".
In this mode, air only circulates without heating or cooling.
2 DRY OPERATION
In this mode, the air humidity will be lowered with a minimal
With icons and text (default)
temperature decrease.
10
11
11
The temperature and fan speed are controlled automatically and
9
cannot be controlled by the remote controller.
Dry operation will not function if the room temperature is too low.
7
1
Heat
Set to
3 AUTOMATIC OPERATION
28
28
3
3
2
°C
°C
In this mode, the controller will automatically switch between
6
4
4
heating and cooling as required by the setpoint.
5
Error: Push Menu button
4 COOLING OPERATION
In this mode, cooling will be activated as required by the setpoint or
limit operation.
With icons and text
5 HEATING OPERATION
15
13
In this mode, heating will be activated as required by the setpoint or
16
setback operation.
13
7
6 VENTILATION (HRV only)
Heat
12
Set to
Room
3
3
The ventilation mode operates the HRV; refer to the HRV manual
14
14
for more details.
Error: Push Menu button
7 SETBACK
SETBACK is a feature that enables to keep the room temperature
in a specific range when the occupants are out and the
airconditioning is switched OFF.
Operation mode
For example:
Heat
Vent
Air Clean
 If the room temperature drops below 10°C, heating is started
automatically. As soon as 12°C is reached, the controller
returns to its original status.
 If the room temperature goes above 35°C, cooling is started
Dry
Auto (Cool)
Auto(Heat)
automatically. As soon as 33°C is reached, the controller
returns to its original status.
The differential can be adjusted in the Setback configuration menu.
The setback temperature can be set during the unit is turned off on
basic screen or set in the schedule.
6.
Basic operation method
a
Cool
c
Return
Return
a Operation mode
b Temperature:
• When the unit is turned on, Set to indicates the
temperatures that are set for the air conditioner.
• When the unit is turned off, Setback indicates the
temperatures that are set for the setback function.
c Fan speed/Airflow direction
indicate the current
1 Push
several times until the desired operation mode Cool,
Heat, Vent, Fan, Dry, or Auto is selected.
indicates that the air cleaning unit
2 Push
. The operation lamp will light and the system starts
operating.
3 Use
to set the temperature.
INFORMATION
When in Dry or Vent mode, the fan speed can not be set.
4 Push
.
5 Use
to select airflow Level or Direction setting.
Airflow level/direction
Level
Direction
Low
Position 0
Return
Return
Setting
Setting
6 With fan speed setting selected, use
fan speed.
INFORMATION
When in Dry or Vent mode, the fan speed can not be set.
7 With airflow direction setting selected, use
setting to Swing, Pos. 0, Pos. 1, Pos. 2, Pos. 3, and Pos. 4.
0
0
1
2
1
3 4
8 Push
to display the basic screen.
9 Push
. The operation lamp will turn off and the system stops
operating.
Additional features of the controller: KEY LOCK
1 Push
for 4 seconds to enable the key lock mode. The key
lock icon is displayed.
Cool
Set to
Cool
Return
Setting
2 To cancel the key lock mode, push
lock icon disappears.
7.
Description of the items in the main menu
1 LOCK
To prohibit buttons, functions or modes.
2 ROTATION
To enable the duty rotation functionality.
(Only available with indoor units that support duty rotation)
1
3 AIRFLOW DIRECTION
/INDIVIDUAL AIR DIRECTION
(only if the individual airflow function is installed)
To set the airflow direction for each 4 flaps individually.
1
4 QUICK START
(SkyAir only)
To quickly set the room temperature to a comfortable temperature.
5 VENTILATION
To set the ventilation rate and the ventilation mode (HRV only).
6 ENERGY SAVING OPTIONS
This allows you to restrict the setting temperature range and
display the energy consumption.
 Setpoint Range Setting
 Energy saving list
 Setback condition
1, 2
 Sensing sensor (Low)
(Only if sensing sensor is installed)
1,
2
 Sensing sensor (Stop)
(Only if sensing sensor is installed)
 Setpoint Auto Reset
 OFF Timer
 Auto display OFF
For more information refer to the detailed user reference
3
guide
1
 Energy Consumption
Set to
1.
This function is not compatible with SkyAir
Cool
RR+RQ units.
2.
In case of a simultaneous operation system, the
b
system is controlled by the sensing sensor
Setting
mounted in the master indoor unit.
3.
The detailed user reference guide and installer
reference guide are available on
www.daikineurope.com/support-and-manuals/
product-information/
.
4
7 SCHEDULE
To set the startup time and operation stop time for any day of the
week. It is possible to set up to 5 actions per day. Both operation
modes (normal and setback) can be selected. Additionally the
holiday settings and schedule nr can be set.
8 MAINTENANCE INFORMATION
Is used to display the service contact and model info.
9 CONFIGURATION
To set the LCD contrast. You can also switch between standard
and detailed display. When detailed display is selected, the detailed
display settings can be changed. You can also set Quiet mode and
Draft prevention.
10 CURRENT SETTINGS
This shows a list of the current settings for the available items.
11 CLOCK & CALENDAR
This allows you to set the date and time. Time can be displayed in
either 12 hour or 24 hour time format.
12 LANGUAGE
This allows you to set the displayed language.
8.
Lock
1 Display the main menu.
2 Press the
button for 4 seconds.
to select the desired
3 Use
to select the Lock item and press
.
4 Use the submenu's to prohibit buttons, functions or modes.
For more information refer to the detailed user reference guide
9.
Rotation
to change the
1 Display the main menu.
2 Push the
button for 4 seconds.
4
3 Use
to select the Rotation function and press
3
2
4 Use the submenu to Enable or Disable Rotation and to
configure the rotation cycle.
For more information refer to the detailed installer reference
3
guide
.
1
10. Airflow direction
/Individual air direction
For more information refer to the detailed user reference guide
1
11. Quick start (SkyAir only)
1 Display the Main Menu and proceed step (9) to display the basic
screen (Refer to
"22. Main menu structure"
and "Appendix").
2 Quick Start will appear on the basic screen when the Quick Start
function is turned ON.
INFORMATION
Repeat this procedure to turn Quick Start function off.
12. Ventilation
for 4 seconds. The key
Only in case an HRV is connected. Refer to the HRV manuals for
more information.
13. Energy saving options
For more information refer to the detailed user reference guide
14. Schedule
14.1 To enable/disable the schedule
1 Display the Enable/Disable setting screen (14.1) (Refer to
menu structure"
and "Appendix").
2 Use
to change the setting to Enable or Disable.
Schedule
Enable/Disable
Disable
Return
Setting
3 Push
to display the confirmation screen.
4 Use
to select Yes and push
.
14.2 To select the schedule number
1 Display the Select Schedule screen (14.2) (Refer to
menu structure"
and "Appendix").
2 Use
to change the setting to Schedule nr 1, Schedule nr 2,
or Schedule nr 3.
Schedule
Select Schedule
Schedule nr 1
Return
Setting
3 Push
to display the confirmation screen.
4 Use
to select Yes and push
.
http://
4.
The schedule will not be available when a
centralised controller or the BRP7A51 Digital
Input Adapter is connected.
14.3 To use the holidays
The schedule timer will be disabled for the days that have been set
as holiday.
1 Display the Holidays screen (14.3) (Refer to
"22. Main menu
structure"
and "Appendix").
2 Use
to select the desired day. Push
to display
to
set the holiday.
Schedule
Holidays
Multiple Selection
Sun Mon Tue Wed Thu Fri Sat
Return
Setting
3 Push
to display the confirmation screen.
4 Use
to select Yes and push
.
14.4 To change the schedule settings of the selected schedule nr
The schedule timer will be disabled for the days that have been set
as holiday.
1 Display the Settings screen (14.4) (Refer to
"22. Main menu
structure"
and "Appendix").
2 Use
to select the desired day (1).
3 Use
to highlight the Operation start Time and
to set
the desired Operation start Time (2).
Schedule nr 1
(2)
3
Time
Act
Cool
Heat
.
(1)
Mon
6
:00
:
:
:
:
Setting
Return
4 Use
to highlight the action and
to select the desired
.
Act.
Schedule nr 1
3
Time
Act
Cool
Heat
Mon
6 :00
:
ON
1
:
:
:
3
.
OFF
2
Setting
INFORMATION (Act column)
There are 3 types of operations:
1.
The temperature setpoints can be configured.
2.
The setback temperature setpoints can be configured.
3.
The temperature and setback temperature setpoints
are disabled.
5 Use
to highlight the temperature and
to select the
desired value.
INFORMATION (Cool and Heat column)
__: Indicates that the temperature setpoint for cool/heat
and setback temperature setpoint for this time period is not
specified. The last active setpoint will be utilized.
- -: Indicates that the setback function is disabled for this
3
.
time period with action OFF.
6 To set a different day of the week, use
to highlight the day.
Use
to change the day.
7 To copy all actions of the day previously set, push
.
"22. Main
8 When the entire schedule settings are completed, push
to
display the confirmation screen.
9 Use
to select Yes and push
.
15. Filter auto clean
This function is available only on the model whose panel has
automatic cleaning function of filter. Needs to be set when
operation is OFF.
16. Maintenance information
1 Display the Maintenance Information screen (16) (Refer to
"22. Main
menu structure"
and "Appendix").
2 The phone number for the Contact info will appear at the top of the
screen. The model info of the Indoor unit and Outdoor unit of your
"22. Main
product will appear on the bottom of the screen.
3 Push
to return to the Main Menu.
17. Configuration
17.1 To select quiet mode enable/disable
1 Display the Quiet Operation Mode settings screen.
2 Display the Enable/Disable screen (17.1) (Refer to
"22. Main
menu structure"
and "Appendix").
3 Use
to select Enable or Disable.
4 Push
to display the confirmation screen.
5 Use
to select Yes and push
.
17.2 To select quiet mode settings
1 Display the Quiet Operation Mode settings screen.
2 Display the Settings screen (17.2).
3 Use
to select the start or End time.
BRC1E53
3P419248-1-KA – 2015.09

Advertisement

loading

Summary of Contents for Daikin 3P419248-1-KA

  • Page 1 Consult 6 ON/OFF BUTTON setting to Swing, Pos. 0, Pos. 1, Pos. 2, Pos. 3, and Pos. 4. your Daikin dealer or authorized contactor for internal 12 AIRFLOW DIRECTION 1 Display the main menu.
  • Page 2 17.3 To select the draft prevention controller case. Cool This is an option to be used in combination with Daikin Set to 1 Display the Draft prevention settings screen (17.3) (Refer to 2. For easy wiring, it’s better to keep ±10 mm difference...

This manual is also suitable for:

Brc1e53