OPERATION

1. Reading the tension knob from the top of the tool, rotate the
knob to select the cross section of cable ties to be installed.
MIN – M: Approx. 0.098" (2.5mm) wide cable ties
(Submin: Approx. 0.070" (1.8mm) wide cable ties)
INT – I:
Approx. 0.142" (3.6mm) wide cable ties
STD – S: Approx. 0.190" (4.8mm) wide cable ties
If necessary, further adjust tension per Tension Adjustment
instructions below.
2. Loop cable tie around bundle and insert the tip through the
head. Pull the tie up snug on the bundle by hand.
3. Insert the strap of the cable tie into the side of the tool. With the
nose of the tool flush to the cable tie head, squeeze the
trigger to tighten the cable tie. Typically, only one depression of
trigger is necessary for cable tie cut-off.

TENSION ADJUSTMENT

There is a tension indicator on the top of the tool. The tension
setting can be changed by turning the fine adjustment knob:
0-3 for MIN; 3-5 for INT; and 6-8 for STD
(0-1 for Subminiature ties)
DAILY TOOL INSPECTION
1. Visually inspect nose area for foreign matter and cable tie scrap. Keep this area clear of foreign matter.
2. Visually inspect applied cable ties for correct tension and cut-off to verify the working condition of the blade and gripper.
PTS Replacement Kits and Accessories Available • Contact Panduit for more information
KGTSBLD
Blade Replacement Kit - For replacement of a worn blade
KPTSTL
Tool Tension Locking Kit - May be installed to prevent adjustment of the tension knob
PHCAQ
Adapter Fitting for Hose (PPH10) - 1/4" Male Quick Disconnect (to regulator).
PHCAT
Adapter Fitting for Hose (PPH10) - 1/4" NPT Male Connection (to regulator).
WB24468D01
Blade Guard Housing - For replacement of a worn blade guard
TECHNICAL SPECIFICATIONS - Air Supply
Recommended regulated air pressure supplied to tool
(pressures other than recommended may result in
unsatisfactory operation):
Air consumption at 30 cycles per minute:
Line pressure supplied to regulator:
Filter/regulator requirements:
Lubrication for air supply:
Recommended filter/regulator unit (supplied by user) with
1/8" NPT ports and 1/4" quick disconnect (industrial
interchange) plug:
Recommended main air supply hose (10 ft.), (supplied by
user) from filter/regulator to tool (supplied by user); includes
a 1/8" NPT male connector (to regulator) and a 1/8" quick
disconnect socket (to tool):
OPERATION INSTRUCTIONS
ITEM
Fine Adjustment Knob
Regulator settings: 75 PSIG (5,2 bar) with a max. 10 PSI
.091 cfm @ 75 PSIG (0,043 l/sec @ 5,2 bar)
Minimum 70 PSIG (4,8 bar), Maximum 90 PSIG (6,2 bar)
5 micron maximum element rating, 5 PSI (0,3 bar) maximum
pressure drop @ 70 PSIG (4,8 bar) inlet pressure and 12
cfm (5,7 l/sec) flow minimum.
Air line lubricators are NOT to be used.
Recommended source: Panduit Part Number PL289N1
Recommended source: Panduit Part Number PPH10
Page: 3 of 20
DESCRIPTION
(0,7 bar) drop. MAXIMUM 90 PSIG
(6,2 bar).
EU Panduit Part Number: MK-06
EU Panduit Part Number:
PPH10G