C. Common Issues
1. Canister power switch does not click when pedal is depressed.
-ThisswitchshouldNOT"click"�Inatypicalswitch,suchastheoneonthemid-sizecanister,theclickyouhearisthemovementofthemetal
contactinsidetheswitch�Thiscontactremainseitherincontact-completingthecircuit,ordis-connected-breakingthecircuit�Thereis
norockerorlatchtoholdthecontactsinplaceinthefull-sizecanistersoyouwillnotheara"click"�Thecircuitismomentarilycompletedby
depressingtheswitch,sendingasignaltothePCboard�Thatsignalisinterpretedasaninstructiontoturnthecanister"On"�Depressing
theswitchasecondtimeinstructsthePCboardtoturnthecanister"Off"�
2. What to check first when canister will not power up.
-Dislodgedelectricalconnectorsaretheusualcauseofthecanisternotpoweringup�Makesurethatalloftheelectricalconnectorsare
firmly and securely engaged. It only takes one dis-connection to interrupt the proper operation of the canister cleaner.
3. Interpreting blinking LED light on the main PC board.
-This light indicates whether the main PC board is maintaining proper communication with the handle PC board� The light should be
blinkingatanapproximaterateof2secondson,2secondsoff�Ifitisblinkingatafasterrateof0�5secondson,0�5secondsoff,thereis
aninterruptioninthecommunicationbetweenthetwoPCboards�Ifthelightdoesnotblinkatall,thereisaproblemwiththepowerbeing
suppliedtothemainPCboard�
4. Canister will not run without the hose connected.
-Thehosemustbeconnectedtocompletethecircuitbeforethecanisterwillrun�Thisisduetothevariablecontrolbeingmountedinthe
handleassembly�
5. Canister cuts on and off at the customers house but runs in the store.
-Thepoweratthehomemayvaryduetothecurrentloadonthecircuit�Wiringinthehousemaynotbeheavyenoughtocarrytheloadof
thecanisterplustheotheritemsconnected�
6. Canister cuts on and off when plugged into a power strip, but runs when plugged into the wall.
-Thepowerstripbreakerisnotlargeenoughtohandlethe12AMPcanisterforextendedperiodoftime�