Clean Mix Chamber Nozzle - Graco Fusion CS20F1 Instructions - Parts Manual

Fusion cs series
Hide thumbs Also See for Fusion CS20F1:
Table of Contents

Advertisement

Maintenance

Clean Mix Chamber Nozzle

1. Engage piston safety lock, page 12.
F
. 39
IG
28
2. Refer to Table 1. Also see identification
chart under Drill Bit Kits, page 53. Use
appropriate size drill bit to clean mix cham-
ber nozzle (N).
TI11326a
F
. 40
IG
Table 1: Nozzle Drill Bit Sizes
Round Spray
Mix
Chamber
RD2020
RD0000
RD0101
RD0202
RD0303
N
Flat Spray
Drill Size
Mix
in. (mm)
Chamber
#58, .042
FL2020
(1.00)
#55, .052
FL0000
(1.30)
#53, .060
FL0101
(1.50)
#50, .070
FL0202
(1.75)
#44, .086
(2.15)
TI12090a
Drill Size
in. (mm)
3/32, .094
(2.35)
3/32, .094
(2.35)
3/32, .094
(2.35)
3/32, .094
(2.35)
312666P