7. TECHNICAL POINT
Valve Drain Assy and Gear Mechanism
We changed the shape of the Lever because of preventing water leakage and noise of G/M.
Please refer to the changing date as following table
Valve Drain Assy
G/M with Tub O
Part name
Plate valve conn'r
Link valve drain
Gear Mechanism
Syncronous Motor
Replacing Process of Synchronous Motor Wire
12
OLD type
Part Cord
Specification
4509k78070
SECC
–
367305900
GM-8094-KS0X0
367305800
GM-1094, KELVAR
4505D45100 L=56.5/18mm(110-130V/60Hz) 4505E45120 L=64.5/23mm(110-130V/60Hz)
3966010200 L=56.5/18mm(220-240V/50Hz) 3966010220 L=64.5/23mm(220-240V/50Hz)
– replace the New G/M
– replace the Link valve drain
from Plate valve connector
– insert the Link v/v drain into the G/M Lever with pulling the Lever toward
Syncronous Motor
– to assemble the wire of Syncronous Motor to the inside of Link valve
drain with pulling the Lever toward Syncronous Motor
NEW type
Part Cord
Specification
–
3617801900
3617307610
GM-1300-KS6P0
POM
DIRECTIONS