Erp Performance Values - Fujitsu Waterstage WOYG112LCTA Maintenance Document

Air to water heat pump split integrated dhw type
Hide thumbs Also See for Waterstage WOYG112LCTA:
Table of Contents

Advertisement

Air to Water Heat Pump (Split integrated DHW type)

ErP performance values

• ErP Definition
"ErP" includes two directives that are part of the program for the reduction of green house gas emission :
Eco-design directive sets effiency thresholds and prohibits the sale of any product with efficiency lower than the set
thresholds.
According to labelling directive, energetic efficiency shall be displayed to encourage end-users to purchase energy-
efficient products.
• Package fiche (HP models)
" application 35 °C
Models
Hydraulic unit reference
Seasonal space heating energy efficiency of
heat pump
Type of temperature control (* = Outdoor
sensor ;** = Room unit)
Bonus
Seasonal space heating energy efficiency of
package under average climate
Energy class of package
Seasonal space heating energy efficiency of
package under warmer climate
Seasonal space heating energy efficiency of
package under colder climate
The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in
a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
" application 55 °C
Models
Hydraulic unit reference
Seasonal space heating energy efficiency of
heat pump
Type of temperature control (* = Outdoor
sensor ;** = Room unit)
Bonus
Seasonal space heating energy efficiency of
package under average climate
Energy class of package
Seasonal space heating energy efficiency of
package under warmer climate
Seasonal space heating energy efficiency of
package under colder climate
The energy efficiency of the package of products provided for in this fiche may not correspond to its actual energy efficiency once installed in
a building, as the efficiency is influenced by further factors such as heat loss in the distribution system and the dimensioning of the products in
relation to building size and characteristics.
Electrical back up heater consumption is taken into account in the performance calculation.
- 80 -
G
F
E
D
< 55%
≥ 55%
≥ 59%
≥ 61% ≥ 100% ≥ 107% ≥ 115% ≥ 123% ≥ 150% ≥ 175%
HP 112 Single
Waterstage . . .
phase type
WGYG140DG6
151%
classe II
classe VI
2%
4%
153%
155%
A++
A++
196%
198%
123%
125%
G
F
E
D
< 30%
≥ 30%
≥ 34%
≥ 36%
HP 112 Single
Waterstage . . .
phase type
WGYG140DG6
109%
classe II
classe VI
2%
4%
111%
113%
A+
A+
119%
121%
102%
104%
C
B
A
A
+
HP 140 Single
HP 112 3-Phase
phase type
WGYG140DG6
WGYK160DG9
148%
154%
classe II
classe VI
classe II
2%
4%
2%
150%
152%
156%
A++
A++
A++
189%
191%
196%
120%
122%
126%
C
B
A
A
+
≥ 75%
≥ 82%
≥ 90%
≥ 98% ≥ 125% ≥ 150%
HP 140 Single
HP 112 3-Phase
phase type
WGYG140DG6
WGYK160DG9
113%
112%
classe II
classe VI
classe II
2%
4%
2%
115%
117%
114%
A+
A+
A+
130%
132%
125%
102%
104%
102%
Installation and operating manual "1768 - EN"
A
++
A
+++
HP 140 3-Phase HP 160 3-Phase
WGYK160DG9
WGYK160DG9
150%
classe VI
classe II
classe VI
classe II
4%
2%
4%
158%
152%
154%
151%
A++
A++
A++
198%
193%
195%
194%
128%
124%
126%
121%
A
++
A
+++
HP 140 3-Phase HP 160 3-Phase
WGYK160DG9
WGYK160DG9
117%
classe VI
classe II
classe VI
classe II
4%
2%
4%
116%
119%
121%
119%
A+
A+
A+
127%
135%
137%
141%
104%
102%
104%
102%
149%
classe VI
2%
4%
153%
A++
A++
196%
123%
117%
classe VI
2%
4%
121%
A+
A+
143%
104%