Problem Of Starting Os - NEC Express5800/R310e-E4 Maintenance Manual

Express5800 series
Hide thumbs Also See for Express5800/R310e-E4:
Table of Contents

Advertisement

Chapter 1 Maintenance
[?]
DISK ACCESS LED is blinking in amber:
Did you properly setup the duplex of HDDs?
 For details about the indication, see Chapter 1 (6.1 Error Indication by LED).
See Chapter 2 (1. Hard Disk Drive Operations), and set up the duplex of HDDs.
[?]
During setting up, Error or Warning logs are recorded in System and Applications Event Log:
 Ignore the logs during setting up.
8.4

Problem of Starting OS

[?]
Unable to start OS:
Are hard disk drives properly installed?
 Install hard disk drives properly.
Is the internal SAS cable connected to hard disk drive correctly?
 Connect the SAS cable properly.
Is the EXPRESSBUILDER DVD inserted?
 Eject the EXPRESSBUILDER DVD and retry.
Is a Flash FDD connected to the server?
 Take out the Flash FDD and restart the server.
[?]
The server repeats rebooting at startup:
Is CHKDSK run at startup?
 Change to Disabled in the following BIOS setting by using BIOS Setup Utility.
Server - OS Boot Monitoring
For details, see Chapter 3 (1. System BIOS).
* After completion of CHKDSK, restart the server and change the above setting back to
Enabled.
CHKDSK is run in the following conditions:
– CHKDSK is scheduled to be run at next startup.
– Corruption of file system is detected since the previous startup until shutdown.
– Inconsistency (corruption) of file system is detected while mounting at startup.
Is the setting of OS Boot Monitoring appropriate?
 Change the setting of OS Boot Monitoring to suit your system environment. See Chapter 3 (1.
System BIOS) for details.