☞. This is the function to use GE314 a
Press <ENT> key and select USE by pressing <4> or <6> key then press <ENT> key for setting.
UNUSE: Normal TTL outputs will be activated.
USE: 26bit Wiegand output will be generated through TTL1 and TTL2 port.
When an registered card is read, the "CARD SCCANNING OK" message will appear on the LCD.
TTL1 : Data 0 TTL2 : Data 1
9.3.8 DOOR OPEN ALARM TIME SETTING
☞. When the door is not closed after the door open time is over, you may set the delay time to generate Door
Open Alarm. To use t
time by Door Contact Sensor. '03' sec. is default time.
00: Alarm if the door is not closed after the door open time (Door Relay time).
01~98: Alarm if the door is not closed after the door open time and over the alarm delay time. (01~98s)
99: No Door Open Alarm
s a Reader and sends 26bit Wiegand Output through two TTL output ports.
his function, you have to install a Door Contact Sensor on the door and setup the alarm