Lenses and Lens Diameters
Maximum outer diameter
Lenses and Lens Diameters
Lens model
3Z4S-LE C418DX
3Z4S-LE B618CX-2
3Z4S-LE C815B
3Z4S-LE B1214D-2
3Z4S-LE C1614A
3Z4S-LE B2514D
3Z4S-LE B5014A
3Z4S-LE B7514C
Extension Tube
One or more Extension Tubes can be inserted between the lens and the Camera to focus the
Camera image.Use a combination of one or more of the six tubes to achieve the required length.
Extension Tube
Maximum outer
Item
diameter
3Z4S-LE EX-C6
31 dia.
• Do not use the 0.5-mm and 1.0-mm Extension Tubes attached to each other.
Since these Extension Tubes are placed over the threaded section of the Lens or other Extension Tube, the
connection may loosen when more than one 0.5-mm or 1.0-mm Extension Tube are used together.
• Reinforcement may be required for combinations of Extension Tubes exceeding 30 mm if the Camera is subject
to vibration.
Total length
Focal length Brightness
Maximum outer diameter
4.8mm
F1.8
40.5 mm dia.
6.5mm
F1.8
48 mm dia.
8.5mm
F1.5
42 mm dia.
12.5mm
F1.4
42 mm dia.
16.0mm
F1.4
30 mm dia.
25.0mm
F1.4
30 mm dia.
50.0mm
F1.4
48 mm dia.
75.0mm
F1.4
62 mm dia.
Extension Tube
20 mm
Length: 40 mm
Lenses, Lighting, and Memory Cards
1"-32UN
30 dia.
-2A
Total length
Filter size
35.5mm
42mm
40mm
M40.5 × P0.5
50mm
33mm
M27 × P0.5
37.3mm
M46 × P0.75
48mm
79mm
M58 × P0.75
Length
10 mm
5 mm
1.0 mm 0.5 mm