Icom IC-RX7 Service Manual Addendum page 44

Hide thumbs Also See for IC-RX7:
Table of Contents

Advertisement

ADJUSTMENT
S-METER CURVE
1
-145 MHz-
(Preparation)
(S0 level)
2
(S3 level)
3
(Full scale)
4
S-METER CURVE
1
-83 MHz-
(Preparation)
(S0 level)
2
(S3 level)
3
(Full scale)
4
COMMON SETTING;
Modulation : 1 kHz
Deviation
: 3.5 kHz (FM)
: 52.5 kHz (WFM)
DISPLAYED ITEM
• Connect an SSG to the antenna connector and set it
as;
1) Set the SSG as;
[S0]
2) Push [ENT MW] key.
1) Set the SSG as;
[S3]
2) Push [ENT MW] key.
1) Set the SSG as;
[SF]
2) Push [ENT MW] key.
• Connect an SSG to the antenna connector and set it
as;
1) Set the SSG as;
[S0]
2) Push [ENT MW] key.
1) Set the SSG as;
[S3]
2) Push [ENT MW] key.
1) Set the SSG as;
[SF]
2) Push [ENT MW] key.
STANDARD SIGNAL GENERATOR
(0.3–1500 MHz)
OPERATION
Modulation : 1 kHz
Deviation
: 3.5 kHz (FM)
Frequency : (Displayed on the function display)
Level
: –9 dBµ
Frequency : (Displayed on the function display)
Level
: –5 dBµ
Frequency : (Displayed on the function display)
Level
: +3 dBµ
Modulation : 1 kHz
Deviation
: 52.5 kHz (WFM)
Frequency : (Displayed on the function display)
Level
: 0 dBµ
Frequency : (Displayed on the function display)
Level
: +3 dBµ
Frequency : (Displayed on the function display)
Level
: +9 dBµ
5 - 4
VALUE
(Automatic
adjustment)
(Automatic
adjustment)