Download Print this page

Specifications - ADC H2TU-R-402 List 5F Quick Installation

Remote unit

Advertisement

T
H2TU-R-402 L
HE
The H2TU-R-402 List 5F (H2TU-R) functions as the remote end of a repeaterless T1
transmission system when connected to a HiGain
Setting new standards for interoperability and efficiency, HiGain HDSL2 modules
transmit 1.544 Mbps T1 payload on one unconditioned copper pair over the full
Carrier Service Area (CSA) range.
F
EATURES
Front panel: status LEDs, craft port for
maintenance screen access, and LBK pushbutton
for activating loopback commands
Maintenance screens for inventory, provisioning,
performance monitoring, troubleshooting,
including:
• Remote provisioning and PM data retrieval
through TL1 FDL or 11-bit inband commands
• Loop attenuation and insertion loss reporting
• Test signal generator
S
PECIFICATIONS
Operating Temperature
Operating Humidity
Line Power Consumption
Electrical Protection
Mounting
HDSL2 Line Rate
HDSL2 Output
DS1 Pulse Output
Maximum Insertion Loss
DS1 Line Rate
DS1 Line Format
DS1 Frame Format
5F
IST
• Power Back Off (PBON and PBOC) for
• Payload retrieval of margin and pulse
• Performance Report Messaging (SPRM,
-40°F to +149°F (-40°C to + 65°C)
5% to 95% non-condensing
4.5 Watts
Secondary surge and power cross-protection on
all DS1 and HDSL2 ports
Any 400 or 200 mechanics shelf
1.552 Mbps Overlapped Pulse Amplitude
Modulated Transmission with Interlocking
Spectra (OPTIS)
+16.5 dBm ±0.5 dBm, 135Ω
0 dB, -7.5 dB, -15 dB
35 dB at 196 KHz, 135Ω
1.544 Mbps ±200 bps
Alternate Mark Inversion (AMI) or Bipolar with
8-zero Substitution (B8ZS)
Extended SuperFrame (ESF), SuperFrame (SF),
or Unframed (UNFR)
®
HDSL2 line unit (H2TU-C).
configuring HDSL2 transmit power to reduce
crosstalk
attenuation parameters (DBDB)
NPRM, and AUTO)