I SELF DIAGNOSIS FUNCTION (DIAG)
This unit has self diagnosis functions that are intended for inspection, measurement and location of faulty point.
There are 21 DIAG menu items, each of which has sub-menu items.
Listed in the table below are menu items and sub-menu items.
No DIAG menu
1
BYPASS
2
RAM THROUGH
3
PRO LOGIC
4
SPEAKERS SET
5
Xch-INPUT
6
MIC CHECK
7
VFD CHECK
STRAIGHT
8
MANUAL TEST
9
DAB CHECK
10 FACTORY PRESET
11 AD DATA CHECK
12 V_CONV_STATUS
13 XM STATUS
12
sub-menu
1. ANALOG BYPASS
2. DSP BYPASS
1. RAM MARGIN
2. RAM FULL BIT
1. PRO LOGIC
1. FRNT: SML 0dB
2. CENTER: NONE
3. LFE/B: FRNT
4. Pres Mix: 5ch
5. FRNT GAIN1
6. FRNT GAIN2
7. SURR B Check
1. XCH INPUT_6
2. XCH INPUT_8
MIC CHK --dB (Not applied to this model)
1. VFD CHECK (Initial display)
2. VFD DISP OFF (All segments OFF)
3. VFD DISP ALL (All segments ON 100%)
4. VFD DIMMER (All segments ON 50%)
5. CHECKED PATTERN (ON in lattice)
1. TEST ALL
2. TEST FRNT L
3. TEST CENTER
4. TEST FRNT R
5. TEST SURR R
6. TEST SB R
7. TEST SB L
8. TEST SURR L
9. TEST PRES L
10. TEST PRES R
11. TEST LFE
1. DAB SCAN/SCL
2. DLS
3. SIGNAL QUALITY
1. PRESET INHI (memory initialization inhibited)
2. PRESET RSRV (memory initialized)
1. DC/PS (protection)
2. THM
3. IMP SW/POWER LIMIT
4. K0/K1 (panel key)
1. LOW BYTE (Not applied to this model)
2. HIGH BYTE (Not applied to this model)
1. XMS1 (Not applied to this model)
2. XMS2 (Not applied to this model)