5H8
1-5-2
Paper feed section
(1) Detaching and refitting PF separation roller 1 and 2
Clean or replace PF separation roller 1 and 2 as follows.
Procedure
1. Open left cover 4.
2. Remove two stop rings (a).
3. Remove the shaft.
4. Remove the PF separation roller assembly.
5. Remove stop ring (b) securing PF separation roller
2 and then the roller.
6. Remove stop ring (c) securing PF separation roller
1 and then the roller.
7. Clean or replace PF separation roller 1 and 2.
8. Refit all removed parts.
1-5-2
Stop ring (a)
Shaft
Service Manual
Left cover 4
PF separation roller 2
Figure 1-5-1
Stop ring (b)
PF separation
roller 1
Stop ring (c)
Stop ring (a)
Y112030-5