Receiver settings

Receiver settings menu

RECEIVER
2.0< >
>ALARM VOLT
3,8V
ALARM TEMP:
70°C
>PERIOD:
20ms
SensoratK5:
No
SUMD at K6:
Yes
S1037_S1012_jh_V1
The receiver can be programmed with a suitable HoTT transmitter
or in connection with the SMART-BOX.
The receiver setup menu appears in the "Telemetry" menu under
SETTINGS / DISPLAYS or if you are using a SMART-BOX under SET-
TING & DATAVIEW. How to access this menu is described in the oper-
ating instructions supplied with your transmitter or Smart-Box.
Low voltage warning (ALARM VOLT):
If the receiver voltage falls below the set value, a low-voltage warn-
ing is generated by the transmitter in the form of a "general alarm
tone" (regular beeping at a rate of approx. one beep per second) or
the "receiver voltage" speech output message.
Temperature warning (ALARM TEMP):
If the receiver temperature exceeds the set temperature, a warning
is generated by the transmitter in the form of a "general alarm tone"
(regular beeping at a rate of approx. one beep per second) or the
"receiver temperature" speech output message.
Cycle time (CYCLE):
Cycle time (PERIOD): If your system is used exclusively with digital
servos, you can set a cycle time (frame rate) of 10 ms. If your system
includes some or uses exclusively analogue servos, you should always
select 20 ms, as many analogue servos cannot process the higher
frame rate and may respond by "jittering" or "growling".
Sensor at channel 5 (K5):
The output channel 5 can be used as servo output or as telemetry
port.
HoTT sum signal at channel 6 (SUMD):
If you activate the digital sum signal at channel 6, a sum signal con-
taining 8 channels is present at this socket, instead of a servo signal.
If the transmitter is configured as SUMD,it generates permanently
from 8 control signals of the transmitter a digital sum signal which is
emitted through the channel 6. This type of signal was being used by
several Flybarless systems and power supplies.