Priming/dispensing only setup guide
Hide thumbs Also See for LDS9000:

Advertisement

ADMINISTRATOR MANUAL
Priming/Dispensing
Only Setup Guide
Dispensing Innovation™

Advertisement

Table of Contents
loading

Summary of Contents for Fishman LDS9000

  • Page 1 ADMINISTRATOR MANUAL Priming/Dispensing Only Setup Guide Dispensing Innovation™...
  • Page 2 Fishman Corporation Fishman Corporation USA Toll Free 1-800-433-2115 USA Toll Free 1-800-433-2115...
  • Page 3 If you are unsure of any step or have questions, consult your SmartDispenser Priming/Dispensing Only ® Setup Guide, contact your Fishman representative, or call us at one of the numbers below. US & Canada: 800-433-2115 United Kingdom: 1905 456008 Europe: +441905 456008 Worldwide: 1-508-435-2115 ®...
  • Page 4: Table Of Contents

    Reservoir to LDAV, MDAV or SDAV Gun 7.0 Dispense Tip Locator 8.0 Prime the Genius FreeFlow ® ™ Dispense Tip 9.0 “Priming Only” and “Dispensing Only” SmartDispenser Setup ® Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 5: Prepare Your Workspace For The Smartdispenser

    1.0 Prepare your workspace for the SmartDispenser ® Be sure your work area has access to electrical power. You will not need compressed air. The SmartDispenser works without air. ® The SmartDispenser ® utilizes a WiFi (USB WiFi adapter included) or Ethernet connection via the back panel for networking,...
  • Page 6: Hook Up Your Smartdispenser Components

    3.0 Hook up your SmartDispenser ® components Refer to the diagram to connect all components and peripheral devices to the SmartDispenser ® (Sold Separately) Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 7 SmartDispenser Components ® A. LDS Push-to- G. USB connectors M. Power Supply Connector Connect H. Ethernet Port Dispense Gun N. On/Off Button I. Cisco Wireless B. Gun Connector O. Power Light Connectivity P. Touch Screen C. Foot Pedal Device Q. Earphone D.
  • Page 8 SmartDispenser . Plug the power cord into ® a power outlet. Connect the 2.5mm earphone to earphone port . (Optional) Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 9: Startup And Logon The

    ® illuminate . The Windows 7 operating system will now begin to boot up and in approximately two minutes the Fishman Home Screen will appear. From here you can navigate to all critical apps and functions. International +00 1 508-435-2115 www.fishmancorp.com 10...
  • Page 10 Tap/click Video icon. On the left navigation panel, tap click “Videos” and select one of the listed syringe filling videos. Fishman Corporation Fishman Corporation USA Toll Free 1-800-433-2115 USA Toll Free 1-800-433-2115 Fishman Corporation...
  • Page 11 On home screen tap/click on the Traditional mode icon. LDS9000 ® Traditional On SmartDispenser Logon screen select ® Administrator from drop down menu. Tap/click password 1234, tap/click OK, tap/click Logon button. Access the Admin button and select the Settings tab. Confirm CORRECT settings for Machine Use Options and Prime Step Count Transfer Method.
  • Page 12 2) Tap/click a second time to get the arrows to separate revealing a slide bar. Tap/click either arrow to increase/ decrease the number or tap/click and hold grey slider rectangle sliding in either direction for rapid number change. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 13 3) Tap/click and hold a third time and keypad will appear. Tap/click “CLR” button and input the desired number. Tap/click “Enter” button. Upon tap/click of “Enter” button the keypad will automatically move to the next dispense parameter. Tip: Use the four arrow keys to move up and down from one dispense parameter to another.
  • Page 14 “0” and the footer buttons set to EXTEND(Retract) and MANUAL(Auto). Note: “Prime Only” function is available exclusively in the Traditional 9000 menu. “Dispense Only” function is available in both Traditional 9000 and PC menus. Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 15: Lds Push-To-Connect Gun Assembly

    5. LDS Push-to-Connect ™ ™ Gun Assembly SurLok ™ Retaining The LDS Push-to- ™ Ring Cover Connect dispense gun ™ are available in different Genius ® configurations. Tip Cap • LDAV (Large Dot Any Viscosity) Genius Syringe ® • MDAV (Medium Dot Any Viscosity •...
  • Page 16: Attach The Genius Barrel Reservoir To Ldav, Mdav Or Sdav Gun

    Manually twist the barrel reservoir in a clockwise direction until the luer lock connector is finger tight and the ears of the barrel reservoir are flush against the retaining plate. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 17 CAUTION: Do not over-tighten the barrel reservoir. It is only necessary to make a loose connection to bring the barrel reservoir flush. The retaining ring holds the barrel reservoir in place. TIP: It may be necessary to tap/click the EXTEND (Retract) EXTEND(Retract) button to RETRACT(Extend) and step on the foot pedal to bring the ears...
  • Page 18: 7.0 Dispense Tip Locator

    Adjust the thumb screw on the rail to approximate the height of the LDS dispense gun with filled syringe barrel and dispense tip attached. Tip Locator Arm Thumb Screw to adjust height Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 19 Engage the tip locator arm by lifting it 90º and lock it in place. Tip Locator Arm in locked postion. Thumb Screw to make micro adjustments EXTEND Use the thumb screw on the arm to make micro height adjustments. www.fishmancorp.com 20 International +00 1 508-435-2115 www.fishmancorp.com International +00 1 508-435-2115...
  • Page 20 If necessary, make a slight adjustment to the luer lock dispense tip until it comes into contact with the end of the thumb screw. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 21 Gently tug the tip locator arm, remove the LDS dispense gun and continue to repeat as necessary. EXTEND www.fishmancorp.com 22 International +00 1 508-435-2115 www.fishmancorp.com International +00 1 508-435-2115...
  • Page 22: Prime The Genius ® Freeflow

    To stop the fluid when flush with the end of the Genius ® dispense tip with no air pockets. If too little fluid: Continue to press on the foot pedal intermittently causing the fluid to flow to the tip. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 23 If too much fluid: On the control panel, tap/click the EXTEND (Retract) button to RETRACT (Extend). Step on the foot pedal in small short pulses until the fluid stops flowing from the tip. EXTEND Goal: To stop the forward motion of the fluid (Retract) by retracting the piston and sucking the fluid back.
  • Page 24: Priming Only" And "Dispensing Only

    ® the Prime Done button again. Enter the name of the designated “Dispensing Only” only unit in the pop up box and select OK. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 25 If you are providing primed guns for multiple “P-T-C Gun Mounts” in the automation system return to step 9.2.1. Dispense Only – USB Configuration The “Dispense Only” unit can be set to either the Traditional LDS9000 or Process Control2 screen ®...
  • Page 26 Done tap/click the Prime Done button. NOTE: After the data has been transferred and accepted by the “Dispensing Only” unit the step count will automatically re-set to 0. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 27 Dispense Only – Serial Configuration 9.4.1 The “Dispense Only” unit can be set to either the Traditional LDS9000 or Process Control2 ® screen with the designated dispense program. The step count in the illustration on the right should be at 0. Tap/click the Enter Steps button.
  • Page 28 With the settings at RETRACT (Extract) and MANUAL (Auto), activate foot pedal or finger switch. This will return the step count to 0 without affecting the gun. Fishman Corporation USA Toll Free 1-800-433-2115 Fishman Corporation USA Toll Free 1-800-433-2115...
  • Page 29 NOTE: If you are priming guns for multiple “Dispensing Only” units it is essential that the guns be labeled or marked in such a way that they only be used with the designated “Dispensing Only” unit. The saved step count information for each gun can vary slightly.
  • Page 30 ® Meets applicable CE requirements. Administrator Manual Priming/Dispensing Only Setup Guide | Version 3 This manual is for the express and sole use of Fishman SmartDispenser users and purchasers, and no portion of this manual ® may be reproduced in any form.
  • Page 31 International +00 1 508-435-2115 www.fishmancorp.com 32 www.fishmancorp.com 32 International +00 1 508-435-2115...
  • Page 32 Fishman Corporation US & Canada: 800-433-2115 192 South Street United Kingdom: 1905 456008 Hopkinton, MA 01748 Europe: +441905 456008 United States Worldwide: 1-508-435-2115 www.fishmancorp.com Fishman Corporation Fishman Corporation USA Toll Free 1-800-433-2115 USA Toll Free 1-800-433-2115...