Wdt Initialization And Configuration; Watchdog Timer Registers - Texas Instruments C2620 Technical Reference Manual

Cc26 series simplelink wireless mcu
Table of Contents

Advertisement

WDT Initialization and Configuration

Control /Interrupt
Interrupt/NMI
INFRASTRUCTURE
clock
15.3 WDT Initialization and Configuration
To use the WDT, its peripheral clock must be enabled. The WDT is running off the infrastructure clock
sourced by the MCU PRCM module. The WDT is then configured using the following sequence:
1. Load the [WDT:LOAD] register with the desired timer load value.
2. If the Watchdog is configured to trigger system resets, set the [WDT:CTL:RESEN] bit.
3. Set the [WDT:CTL:INTEN] bit to enable the WDT.
4. Lock the WDT module using [WDT:LOCK].

15.4 Watchdog Timer Registers

1144
Watchdog Timer
Figure 15-1. WDT Block Diagram
generation
[WDT:CTL]
[WDT:ICR]
[WDT:RIS]
[WDT:MIS]
[WDT:LOCK]
Copyright © 2015, Texas Instruments Incorporated
[WDT:LOAD]
32±Bit down counter
0x 00000000
Comparator
SWCU117A – February 2015 – Revised March 2015
www.ti.com
[WDT:VALUE]