IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint,
paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These
fumes may mix with combustion air and create odors. These odors will disappear over time.
OBSERVED PROBLEM
Remote does not function
Heater produces a clicking/tick-
ing noise just after burners are lit
or shut off
Heater produces unwanted
odors
Heater shuts off in use (ODS
operates)
Gas odor even when control knob
is in OFF position
Gas odor during combustion

Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
TROUbLESHOOTING
Continued
POSSIBLE CAUSE
1. Battery is not installed. Bat-
tery power is low
1. Metal expanding while heating
or contracting while cooling
1. Heater burning vapors from
paint, hair spray, glues, clean-
ers, chemicals, new carpet,
etc. (See IMPORTANT state-
ment above)
2. Low fuel supply (propane/LP
only)
3. Gas leak. See Warning
statement at top of page
1. Not enough fresh air is avail-
able
2. Low line pressure
3. O D S / p i l o t i s p a r t i a l l y
clogged
1. Gas leak. See Warning
statement at top of page
2. Control valve defective
1. Foreign matter between con-
trol valve and burner
2. Gas leak. See Warning
statement at top of page
REMEDY
1. Replace 4 AA batteries in
receiver and 3 AAA batteries
in hand-held remote control
1. This is common with most heat-
ers. If noise is excessive, contact
qualified service person
1. Open window to ventilate
room. Stop using odor caus-
ing products while heater is
running
2. Refill supply tank (propane/
LP only)
3. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)
1. Open window and/or door for
ventilation
2. Contact local natural or pro-
pane/LP gas company
3. Clean ODS/pilot (see Cleaning
and Maintenance, page 21)
1. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)
2. Replace control valve
1. Take apart gas tubing and
remove foreign matter
2. Locate and correct all leaks
(see Checking Gas Connec-
tions, page 15)