Summary of Contents for Siemens CPU 1518-4 PN/DP ODK

  • Page 2 ___________________ CPU 1518-4 PN/DP ODK (6ES7518- Preface 4AP00-3AB0) ___________________ Documentation guide ___________________ SIMATIC Product overview ___________________ Connecting up S7-1500 CPU 1518-4 PN/DP ODK Interrupts, error messages, ___________ diagnostics and system (6ES7518-4AP00-3AB0) alarms ___________________ Manual Technical specifications ___________________ Dimensional drawing 09/2016...
  • Page 3: Legal Information

    Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 4: Preface

    All cross-system functions are described in the system manual and in the function manuals. The information provided in this manual and the system manual enables you to commission the CPU 1518-4 PN/DP ODK. Basic knowledge required To understand this documentation, you need to have general knowledge of automation engineering.
  • Page 5 In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens’ products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks.
  • Page 6 Preface Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). Catalogs for all the products in automation and drives are available on the Internet (https://mall.industry.siemens.com).
  • Page 7: Table Of Contents

    Mode selector switch ......................27 Connecting up ............................28 Interrupts, error messages, diagnostics and system alarms ..............33 Status and error display of the CPU ..................33 Technical specifications ........................36 Dimensional drawing ..........................48 CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 8: Documentation Guide

    CPU 1516pro-2 PN you use the corresponding operating instructions. The STEP 7 online help supports you in the configuration and programming. Device information Product manuals contain a compact description of the module-specific information, such as properties, wiring diagrams, characteristics and technical specifications. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 9 You must register once to use the full functionality of "mySupport". You can find "mySupport" on the Internet (https://support.industry.siemens.com/My/ww/en). "mySupport" - Documentation In the Documentation area in "mySupport" you can combine entire manuals or only parts of these to your own manual.
  • Page 10 With the TIA Selection Tool, you can generate a complete order list from your product selection or product configuration. You can find the TIA Selection Tool on the Internet (http://w3.siemens.com/mcms/topics/en/simatic/tia-selection-tool). CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 11 You can find the SIMATIC Automation Tool on the Internet (https://support.industry.siemens.com/cs/ww/en/view/98161300). PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the PROFINET network during commissioning. PRONETA features two core functions: ● The topology overview independently scans PROFINET and all connected components.
  • Page 12: Product Overview

    The controller can be retrofitted with additional modules at any time to expand its range of tasks. High industrial capability from the high resistance to EMC, shock and vibration enable universal use of the SIMATIC S7-1500. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 13 The CPU can be used for the high-end area of machine and plant automation. The CPU 1518-4 PN/DP ODK can execute blocks that were programmed with C/C++. Programming of the blocks is effected by means of the "Open Development Kit ODK 1500S"...
  • Page 14 CPU 1517TF- 3 PN/DP CPU 1518F-4 P Fail-safe CPU for high- 26 MB 1 ns N/DP performance applications, demanding communica- CPU 1518F-4 P tion tasks and very short N/DP ODK reaction times CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 15 Integrated digital inputs/outputs 16 inputs/16 outputs 32 inputs/32 outputs High-speed counters Pulse generators 4 (PTOx/PWMx) 4 (PTOx/PWMx) PWM (pulse-width modulation) • PTO (pulse train output or stepper motor control) • Frequency output • CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 16 Improved manipulation protection allows changed or unauthorized transfers of engineering data to be detected by the controller. The use of an Ethernet CP (CP 1543-1) provides you with additional access protection through a firewall or possibilities to establish secure VPN connections. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 17 The CPU is available as a central interrupt server for 3 languages. The CPU, STEP 7 and your HMI guarantee data consistency without additional engineering steps. The maintenance work is easier. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 18: How It Works

    SIMATIC memory card and is processed in the work memory of the CPU. CPU 1518-4 PN/DP ODK allows you to integrate C/C++ functions created with the SIMATIC S7-1500 ODK in the user program in addition to the user program created directly with STEP The connection to the process is centralized or distributed via PROFINET or PROFIBUS with I/O modules.
  • Page 19: Properties

    2.3 Properties Properties Article number 6ES7518-4AP00-3AB0 View of the module The figure below shows the CPU 1518-4 PN/DP ODK. Figure 2-1 CPU 1518-4 PN/DP ODK Note Protective film Note that a protective film is attached to the display of the CPU when shipped from the factory.
  • Page 20 PN/DP ODK. ● Communication: – Interfaces CPU 1518-4 PN/DP ODK has four interfaces. Three interfaces for PROFINET and one for PROFIBUS. The 1st PROFINET interface (X1 P1, X1 P2) has two ports. In addition to PROFINET basic functionality, it also supports PROFINET IO RT (real-time) and IRT (isochronous real-time).
  • Page 21 – Display of trace recording stored on the SIMATIC memory card – Readout service data – Basic Web pages – Display of the Web server in 3 project languages, for example, comments and message texts – Recipes – User-defined Web pages CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 22 – The alarms for the system diagnostics are automatically created by the system and displayed on a PG/PC, HMI device, Web server or the integrated display. System diagnostics information is also available when the CPU is in STOP mode. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 23 You can find information about the "Isochronous mode" topic in the PROFINET (http://support.automation.siemens.com/WW/view/en/68039307) function manual. Reference You will find additional information on the topic of "Integrated security/Access protection" in the S7-1500/ET 200MP system manual (http://support.automation.siemens.com/WW/view/en/59191792). CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 24: Operating And Display Elements

    Operating and display elements 2.4.1 Front view of the module with closed front panels The figure below shows the front view of the CPU 1518-4 PN/DP ODK. ① LEDs for the current operating mode and diagnostic status of the CPU ②...
  • Page 25 (http://support.automation.siemens.com/WW/view/en/59191792) system manual. Reference You will find detailed information on the individual display options, a training course and a simulation of the available menu commands in the SIMATIC S7-1500 Display Simulator (http://www.automation.siemens.com/salesmaterial-as/interactive-manuals/getting- started_simatic-s7-1500/disp_tool/start_en.html). CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 26: Front View Of The Module Without Front Panels

    Slot for the SIMATIC memory card ⑫ Display connector ⑬ LEDs for the current operating mode and diagnostic status of the CPU Figure 2-4 View of the CPU 1518-4 PN/DP ODK (without front panels) - front CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 27: Rear View Of The Module

    ③ Fixing screws Figure 2-5 View of the CPU 1518-4 PN/DP ODK - rear Mode selector switch Use the mode switch to set the CPU operating mode. The following table shows the position of the switch and the corresponding meaning.
  • Page 28: Connecting Up

    Connecting up This section provides information on the terminal assignment of the individual interfaces and the block diagram of the CPU 1518-4 PN/DP ODK. 24 V DC supply voltage (X80) The connector for the power supply is plugged in when the CPU ships from the factory.
  • Page 29 (MDI) or a switch (MDI-X). ● Autocrossing is always active on X3. This means the RJ45 socket is allocated either as data terminal equipment (MDI) or a switch (MDI-X). Figure 3-2 Interfaces X2 and X3 CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 30 Note Supply of I/O devices The CPU 1518-4 PN/DP ODK does not provide a 24 V DC power supply on the PROFIBUS interface. I/O devices (for example, PC adapter USB 6ES7972-0CB20-0XA0) are only operational on the interface in conjunction with a plug-in power supply set for external power supply.
  • Page 31 The number range of the MAC addresses is sequential. The first and last MAC address are lasered on the rating plate on the right side of each CPU 1518-4 PN/DP ODK. The table below shows how the MAC addresses are assigned.
  • Page 32 Connecting up Block diagram The figure below shows the block diagram of the CPU 1518-4 PN/DP ODK. ① Display PN X1 P2 R PROFINET interface X1 Port 2 ② RUN/STOP/MRES mode selector PN X2 P1 PROFINET interface X2 Port 1 ③...
  • Page 33: Interrupts, Error Messages, Diagnostics And System Alarms

    Interrupts, error messages, diagnostics and system alarms The status and error displays of the CPU 1518-4 PN/DP ODK are described below. You will find additional information on "Interrupts" in the STEP 7 online help. You can find additional information on the topics of "Diagnostics" and "System alarms" in the Diagnostics (http://support.automation.siemens.com/WW/view/en/59192926) function...
  • Page 34 4.1 Status and error display of the CPU Meaning of the RUN/STOP, ERROR and MAINT LEDs The CPU 1518-4 PN/DP ODK has three LEDs to signal the current operating status and diagnostics status. The following table shows the meaning of the various combinations of colors for the RUN/STOP, ERROR and MAINT LEDs.
  • Page 35 4.1 Status and error display of the CPU Meaning of LINK RX/TX LED Each port has a LINK RX/TX LED. The table below shows the various "LED scenarios" of ports for the CPU 1518-4 PN/DP ODK. Table 4- 2 Meaning of the LEDs...
  • Page 36: Technical Specifications

    24 W Memory Number of slots for SIMATIC memory card SIMATIC memory card required Work memory Integrated (for program) 4 MB Integrated (for data) 20 MB Integrated (for ODK application) 20 MB CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 37 Number of asynchronous error OBs Number of synchronous error OBs Number of diagnostic interrupt OBs Nesting depth Per priority class Counters, timers and their retentivity S7 counters Quantity 2048 Retentivity Adjustable • CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 38 • interface, 8 KB via the integrated DP interface Of which per CM/CP 8 KB Inputs (volume) • 8 KB Outputs (volume) • Process image partitions Number of process image partitions, max. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 39 AS, Master in AS, Slave On Ethernet via NTP Interfaces Number of PROFINET interfaces Number of PROFIBUS interfaces 1st interface Interface hardware Number of ports Integrated switch RJ45 (Ethernet) Yes; X1 CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 40 4 ms • Update time = set "odd" send clock (any multiple with IRT and "odd" send clock parameter as- • of 125 µs: 375 µs, 625 µs to 3 875 µs) signment CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 41 Number of IO controllers with shared device, • max. 2nd interface Interface hardware Number of ports Integrated switch RJ45 (Ethernet) Yes; X2 Protocols PROFINET IO controller PROFINET IO device SIMATIC communication Open IE communication Web server Media redundancy CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 42 • S7 routing • Isochronous mode • Open IE communication • • • MRPD • PROFIenergy • Prioritized startup • Shared device • Number of IO controllers with shared device, • max. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 43 64; in total, only 16 S7 routing connections are supported via PROFIBUS SIMATIC communication S7 communication, as server S7 communication, as client User data per job, max. See online help (S7 communication, user data size) CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 44 • Additional protocols MODBUS Yes; MODBUS TCP Media redundancy Switchover time in the case of cable break, typ. 200 ms; with MRP; bumpless with MRPD Number of devices in the ring, max. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 45 Number of tags, max. Diagnostics buffer Available Number of entries, max. 3200 1000 Of which are power failure-proof • Traces Number of configurable traces 8; up to 512 KB data possible per trace CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 46 Vertical mounting position, max. 40 ℃; display: 40 ℃, the display is switched off at an operating temperature of typically 40 ℃ Ambient temperature during storage/transport Min. -40 °C Max. 70 °C CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 47 1988 g General technical specifications You can find information on the general technical specifications, such as standards and approvals, electromagnetic compatibility, protection class, etc., in the S7-1500, ET 200MP (http://support.automation.siemens.com/WW/view/en/59191792) system manual. CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...
  • Page 48: Dimensional Drawing

    Dimensional drawings for CPU 1518-4 PN/DP ODK Figure A-1 Dimensional drawing of CPU 1518-4 PN/DP ODK, front and side views Figure A-2 Dimensional drawing CPU 1518-4 PN/DP ODK, side view with open front panel CPU 1518-4 PN/DP ODK (6ES7518-4AP00-3AB0) Manual, 09/2016, A5E35681108-AA...

This manual is also suitable for:

Simatic s7-15006es7518-4ap00-3ab0

Table of Contents