Chapter 2

2.3.2.7 Air Flow

2.3.2.7.1 Air flow

iPF6100 / iPF6200 / iPF6000S / iPF6300 / iPF6350 / iPF6300S
This printer has two fans, a mist fan used to collect mist and a suction fan used to suck media onto the platen.
Ink mist that floats inside the printer and ink splashes from the media are collected in the filter through the front duct and the air flow path inside the printer by the
driving of the mist fan, thus preventing mist from discharged outside the printer.
During operation of the suction fan, suspended substances are collected in the filter through the airflow path inside the printer, preventing them from being emitted
to outside of the printer.
2-44
Mist fan
F-2-34
Suction fan
F-2-35
Fan filter
Fan filter